Troubleshooting
Debug and Syslog Messaging Operation
Operating Notes for Debug and Syslog
■ Rebooting the Switch or pressing the Reset button resets the
Debug Configuration.
Debug Option Effect of a Reboot or Reset
logging (destination) If any Syslog server IP addresses are in the startup-config file,
they are saved across a reboot and the logging destination
option remains enabled. Otherwise, the logging destination is
disabled.
Session (destination) Disabled.
ACL (event type) Disabled.
All (event type) Disabled.
Event (event type) If a Syslog server is configured in the startup-config file, resets
to enabled, regardless of prior setting. Disabled if no Syslog
server is configured.
IP (event type) Disabled.
■ Debug commands do not affect message output to the Event Log.
As a separate option, invoking debug with the event option causes the
switch to send Event Log messages to whatever debug destination(s) you
configure (session and/or logging), as well as to the Event Log.
■ Ensure that your Syslog server(s) will accept Debug messages. All
Syslog messages resulting from debug operation carry a “debug” severity.
If you configure the switch to transmit debug messages to a Syslog server,
ensure that the server’s Syslog application is configured to accept the
“debug” severity level. (The default configuration for some Syslog appli-
cations ignores the “debug” severity level.)