Chapter 7 Replacing Parts
NOTE The heat sink on your HP Server tc2110 may look different than the one shown in the
illustration and secure with thumb latches instead of screws.
Figure 7-13. Replacing Heat Sink-Cooling Fan on the Processor
CAUTION Ensure you have made good contact with the processor to avoid thermal overheating. If
you have not made good contact with the processor, it will overheat within 20 seconds of
power on, possibly causing a system crash before completing the boot process and
causing damage to the processor.
13. Connect the cooling fan power cable to the fan connector on the system board.
CAUTION Failure to connect the cooling fan to its power connector may cause the Server to shut
down with no messages displayed and possibly damage the processor.
14. Replace the left side cover.
15. Replace the external cables and power cord.
16. Power on the Server as described in Chapter 1, “Controls and Indicators.”
You may have to reboot the Server so the BIOS will recognize the new processor.
Accessory Boards
The system board in the HP Tower Server tc2110 provides one AGP card (installed) and three PCI slots (P1
through P3). The SCSI model requires the first slot (P1) for the SCSI controller board. For a list of tested PCI
boards, check for compatibility in the Hardware Tested Products list for the HP Server tc2110 under the
Technical Support topic for the specific NOS used in the Server at HP’s web site:
http://www.hp.com/
Removing Accessory Boards
To remove an accessory board, refer to the following procedure.
1. If the Server is operating, power off the Server.
Refer to Chapter 1, “Controls and Indicators” for instructions.