4–62 Maintenance and Service Guide
Removal and replacement procedures
The thermal material must be thoroughly cleaned from the surfaces of the fan/heat sink assembly and the system
board each time the fan/heat sink assembly is removed:
Thermal paste is used on the processor 1 and the heat sink section 2 that services it.
Thermal pads are used on the Northbridge chip 3 and the heat sink section 4 that services it.
Thermal pads are used on various other system board components 5 and 7, and heat sink sections 6 and 8
that service them.
Replacement thermal material is included with all fan/heat sink assembly, system board, and processor spare
part kits.
Reverse this procedure to install the fan/heat sink assembly.