HP LH4r - NetServer - 256 MB RAM Technical Information Seite 25

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 158
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 24
24
xSeries 220 Internal SCSI Cabling
Non-Hot-Swap
Models
xSeries 220 nonhot-swap models are cabled internally with a five-drop, 16-bit wide LVD SCSI cable with a built-in multi-mode active terminator on one end of the
cable. The other end of the cable is attached to the internal 68-pin connector of the integrated Ultra160 SCSI controller. SCSI devices can be connected to any of the
five cable connectors. If 8-bit (narrow) devices are to be installed, a 68- to 50-pin converter (32G3925) is required for each narrow device.
Hot-Swap Models
xSeries 220 hot-swap models are cabled internally with a two-drop, 16-bit wide LVD SCSI cable. One end is connected to the internal 68-pin connector of the
integrated Ultra160 SCSI controller. The first drop is designed to support a SCSI device in the 3.5-inch non-hot-swap bay, while the second drop is connected to the
hot-swap SCSI backplane.The SCSI backplane provides termination for the SCSI bus.
Other Configuration Alternatives
In the case where a RAID controller is used to support internal drives in a xSeries 220, the standard cable is moved from the onboard controller to the RAID adapter.
To connect a tape drive to the onboard or other supported SCSI controller, the two-drop cable from Media Bay Tray and LVD Cable Kit (P/N 10K2340) must be used.
External SCSI support can be obtained by installing an optional SCSI adapter or RAID controller and using appropriate external SCSI cabling.
External Storage Expansion Units
3
Form Factor
35311RU EXP300 Storage Expansion Unit
4
Rack (3U)
09N7296 EXP300 Rack-to-Tower Conversion Kit -
1. Nonhot-swap HDDs are supported in bays four through seven of nonhot swap models and in bay four of hot-swap
models.
2. Hot-swap HDDs are supported in bays five through seven of hot-swap models. Bay four supports nonhot-swap
HDDs only.
3. Not supported by the onboard SCSI controller. Select an optional SCSI controller then refer to Appendix D: Cables
- Storage Units - Controllers to confirm the controller supports the desired External Storage Expansion Unit and to
select a supported cable. For HDD or other expansion unit options, see the specific expansion unit section.
4. EXP300 includes a single 2M Ultra2 SCSI cable and dual hot-swap 500W redundant power supplies, each with its
own power cord. To convert an EXP300 to a tower form factor, EXP300 Rack-to-Tower Conversion Kit (P/N 09N7296)
is required.
Bay Form
Factor
Height Front
Access
Usage
1
133mm
(5.25in)
HH yes
IDE CD-
ROM
2
133mm
(5.25in)
HH yes open
1
3
89mm
(3.5in)
SL yes Floppy
4
89mm
(3.5in)
SL yes open
5 ... 7
89mm
(3.5in)
SL
2
yes open
1. This bay does not support HDD options. It can be used for
removable media devices such as tape drives.
2. These bays will be configured as hot-swap bays on models -2AX,
-3AX, -4AX and -5AX.
Bay 4
CD-ROM
Bay 2
Diskette
Bay 5
Bay 6
Bay 7
Seitenansicht 24
1 2 ... 20 21 22 23 24 25 26 27 28 29 30 ... 157 158

Kommentare zu diesen Handbüchern

Keine Kommentare