1.15 Rotor
1.15.1 Rotor RPM (N
R
) – Power On
Minimum 97%
Continuous 97 to 100%
Maximum 100%
1.15.2 Rotor RPM (N
R
) – Power Off
Minimum 91%
Maximum 104.5%
1.16 Hydraulic
Both hydraulic systems shall be operative prior to takeoff.
1.16.1 Hydraulic Oil
Hydraulic fluid type MIL-H-5606 (NATO H-515) shall be used at all ambient
temperatures.
1.16.2 Hydraulic Pressure
Minimum 600 PSI
Caution range 600 to 900 PSI
Normal operating 900 to 1100 PSI
Maximum 1100 PSI