HP d212 Bedienungsanleitung Seite 100

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 177
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 99
FMS-D212-725-1
Page 3-24
• COPYRIGHT © 2007 BY DART AEROSPACE LTD •
This document is private and confidential and is supplied on the express condition that it is not to be used for any
purpose or copied or communicated to any other person without written permission from Dart Aerospace Ltd.
Revision:
D
TC Approved Date: 08.12.17
3.10.2 Heater Overheat
Indications:
1. HEATER O/HEAT caution light illuminates.
2. High temperature detected in heater ducting.
Procedure:
1. HEATER switch – OFF immediately.
2. CABIN HTR circuit breaker – Check; if out, do not reset. If not out,
pull breaker
3. Check prior to next flight.
3.11 Warning and Caution Lights Messages
Red warning lights/messages, fault conditions and corrective actions are
presented in Table 3-1
Amber caution lights/messages, fault conditions and corrective actions are
presented in Table 3-2.