Configuring temperature alarm thresholds for a
card
Use the following command to set temperature alarm thresholds for a card. When the temperature of
a card exceeds a threshold, the router generates alarm signals.
To configure temperature alarm thresholds for a card:
Ste
Command Remarks
1. Enter system view.
system-view N/A
2. Configure temperature alarm
thresholds for a card.
temperature-limit slot slot-number hotspot sensor-num
LowerLimit WarningLimit [ AlarmLimit ]
Optional.
Displaying temperature information for a router
Use the display environment command to display the temperature information of the sensors on the
cards, including the current temperature and temperature thresholds.
# Display the temperature information of the cards on the router.
<Sysname> display environment
System temperature information (degree centigrade):
-------------------------------------------------------------------------------
Slot Sensor Temperature LowerLimit WarningLimit AlarmLimit ShutdownLimit
0 hotspot 1 39 0 70 85 N/A
0 hotspot 2 40 20 80 95 N/A
3 hotspot 1 55 -10 60 80 N/A
3 hotspot 2 42 -5 65 85 N/A
Table 12 Command output
Field Descri
tion
Slot Slot number of a card.
Sensor Temperature sensor, where "hotspot" indicates the hotspot temperature sensor.
Temperature Current temperature.
Lower limit Lower limit of temperature.
WarningLimit Upper limit of temperature for warning.
AlarmLimit Upper limit of temperature for alarming.
ShutdownLimit Upper limit of temperature for shutting down the router (currently not supported).
Configuring in-service hardware failure diagnosis
A hardware failure may cause traffic forwarding failures and service interruption. To improve the
automatic failure detection and handling capabilities of the router, you can configure in-service
hardware failure diagnosis.