HP Elite 8300 Series Small Form Factor Spezifikationen Seite 201

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 349
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 200
Hood Sensor
Description Spare part number
Hood sensor 638816-001
The hood sensor is attached in a slot in the rear of the chassis.
1. Prepare the computer for disassembly (
Preparation for Disassembly on page 160).
2. Remove the access panel (
Access Panel on page 161).
3. Unplug the sensor cable from the system board connector labeled HSENSE (1).
4. Slide the hood sensor straight out of the notch in the chassis (2).
NOTE: A flat blade screwdriver can be used to push the hood sensor out of the slot.
Figure 8-31 Removing the hood sensor from the chassis fan
To install the hood sensor, reverse the removal procedure.
190 Chapter 8 Removal and Replacement Procedures Small Form Factor (SFF) Chassis