Hp E1459A Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Hp E1459A herunter. HP E1459A User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 112
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Artisan Technology Group is your source for quality
new and certied-used/pre-owned equipment
FAST SHIPPING AND
DELIVERY
TENS OF THOUSANDS OF
IN-STOCK ITEMS
EQUIPMENT DEMOS
HUNDREDS OF
MANUFACTURERS
SUPPORTED
LEASING/MONTHLY
RENTALS
ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specications, manuals, and documentation
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
SM
View
Instra
Seitenansicht 0
1 2 3 4 5 6 ... 111 112

Inhaltsverzeichnis

Seite 1 -

Artisan Technology Group is your source for quality new and certied-used/pre-owned equipment• FAST SHIPPING AND DELIVERY• TENS OF THOUSANDS OF IN-S

Seite 2 - Contents

NO POSTAGENECESSARYIF MAILEDIN THEUNITED STATESfold herePlease fold and tape for mailingReader Comment SheetHP E1459A / Z2404B 64-Channel Isolated Inp

Seite 3 - 2 Contents

HP E1459A Register Definitions 99DATA REGISTERS for each port.100 CLEAR SCREEN110 DIM A$[40]120 Vxi_address=70900130 !140 CLEAR 7150 OUT

Seite 4 - Contents 3

100 HP E1459A Register Definitions 510 OUTPUT Vxi_address;"STAT:OPER:ENAB 256"520 OUTPUT Vxi_address;"DIAG:INT:SET1 ON"530

Seite 5 - 4 Contents

HP E1459A Register Definitions 1011030 ENTER Vxi_address;A01035 ! get neg edge register, port 01040 OUTPUT Vxi_address;"VXI:READ? 128,22&quo

Seite 6

102 HP E1459A Register Definitions 1470 A=BINAND(A0,-256) 1480 PRINT "Wrd 0 Pos Edge: ";A1490 A=BINAND(A

Seite 7 - Documentation History

HP E1459A Register Definitions 1031970 ENDArtisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Seite 8

104 HP E1459A Register Definitions Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Seite 9

Error Messages 105Appendix CError MessagesThe following table lists error message and possible cause associated with the HP E1459A Module.Error Desc

Seite 10 - BUSINESS REPLY MAIL

106 Error Messages Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Seite 11

IndexIndex 107Symbols*CLS, 70*DMC, 70*EMC, 70*EMC?, 70*ESE, 70*ESE?, 70*ESR?, 70*GMC?, 70*IDN?, 70*LMC?, 70*OPC, 70*OPC?, 70*PMC, 70*RCL, 70*RMC, 7

Seite 12 - Functional Description

108 IndexIIEEE 488.2 Common Commands, 39, 70Implied Commands, 40Input Data Capture, 17Input Debounce Processing, 14Input Edge Detection, 15Input Is

Seite 13 - Transceivers

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Seite 14

Index 109EVENt?, 65PRESet, 65QUEStionableCONDition?, 66ENABle, 66ENABle?, 67EVENt?, 67SYSTemCDEScription?, 68CTYPe?, 68ERRor?, 69VERSion?, 69TTermi

Seite 15 - Debounce Parameters

110 IndexArtisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Seite 16 - Detection

Artisan Technology Group is your source for quality new and certied-used/pre-owned equipment• FAST SHIPPING AND DELIVERY• TENS OF THOUSANDS OF IN-S

Seite 17 - Examples

Installing and Configuring the HP E1459A 11Chapter 1Installing and Configuring the HP E1459AThe HP E1459A 64-Channel Isolated Digital Input/Interrup

Seite 18

12 Installing and Configuring the HP E1459A Figure 1-1. HP E1459A 64-Channel Isolated Digital Input/Interrupt Block DiagramTo VXIbusTransceiversArtis

Seite 19 - Operations

Installing and Configuring the HP E1459A 13The HP E1459A can be programmed to monitor channel occurrences either internally with a 1.0 MHz sample cl

Seite 20 - Configuring for Installation

14 Installing and Configuring the HP E1459A Watchdog Timer The HP E1459A provides a programmable timer facility which, in the event of time-out, will

Seite 21 - Priority

Installing and Configuring the HP E1459A 15Caution The user MUST ensure, based upon the programmed debounce period and internal delays, that data to

Seite 22 - Watchdog Timer

16 Installing and Configuring the HP E1459A Edge DetectionExamplesFigure 1-3 demonstrates a typical example. A channel that has been programmed to de

Seite 23 - Connecting User

Installing and Configuring the HP E1459A 17Input Data Capture The state of any channel, within any channel group, may be captured for subsequent pro

Seite 24

18 Installing and Configuring the HP E1459A Front Panel Markers All "Data Available" and "Edge Detect" marker bits are physically

Seite 25 - VXIbus Mainframe

ContentsContents 1Warranty ...

Seite 26

Installing and Configuring the HP E1459A 19Configuring for InstallationBefore installing the module you should verify that the following jumpers and

Seite 27 - Wiring a Terminal

20 Installing and Configuring the HP E1459A Setting the LogicalAddressEach module within the VXIbus mainframe must be set to a unique logical address

Seite 28

Installing and Configuring the HP E1459A 21Setting InputThreshold LevelsThe threshold levels for each channel can be set independently. A six pin pl

Seite 29

22 Installing and Configuring the HP E1459A Connecting UserInputsThe HP E1459A Isolated Digital Input/Interrupt module consists of a component module

Seite 30 - Using the HP E1459A Module

Installing and Configuring the HP E1459A 23Figure 1-7. Front Panel ConnectionsA B C32 CH 00 HI CH 00 LO31 CH 01 HI CH 02 LO CH 01 LO30 CH 02 HI CH 0

Seite 31 - Power-on / Reset States

24 Installing and Configuring the HP E1459A Installing the HPE1459A in aVXIbus MainframeThe HP E1459A may be installed in any C-size VXIbus mainframe

Seite 32 - Close Sessions

Installing and Configuring the HP E1459A 25Terminal Block The HP E1459A includes both the input / interrupt module and a screw-type standard termina

Seite 33 - Digital Input

26 Installing and Configuring the HP E1459A Wiring a TerminalBlockThe following illustrations show how to connect field wiring to the terminal block.

Seite 34

Installing and Configuring the HP E1459A 275Replace Wiring Exit PanelCut requiredholes in panelsfor wire exitKeep wiring exit panelhole as small asp

Seite 35 - Edge Detected Event Detection

28 Installing and Configuring the HP E1459A Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Seite 36

2 ContentsChapter 3HP E1459A SCPI Command Reference ...39DIAGnostic:SYSReset Subsy

Seite 37

Using the HP E1459A Module 29Chapter 2Using the HP E1459A ModuleThis chapter provides examples of using and programming the HP E1459A using the Stan

Seite 38 - Edge Interrupt

30 Using the HP E1459A Module Power-on / Reset StatesAt power-on or reset (*RST) the HP E1459A is set to the following conditions:• Watchdog timer is

Seite 39 - Enable Port 0 Edge Detection

Using the HP E1459A Module 31/* Send the Self Test Command */errStatus = viQueryf (E1459, "*TST?\n","%t",selftst_string);if (VI_

Seite 40 - SCPI Command Format

32 Using the HP E1459A Module Digital Input The HP E1459A is capable of simple digital inputs on any of the individual four ports or combined Ports 0

Seite 41

Using the HP E1459A Module 33/* Query Ports 2 and 3 as a 32-bit word */errStatus = viQueryf(E1459, "MEAS:DIG:DATA2:LWORD:VAL?\n","%t&

Seite 42 - DIAGnostic:SYSReset Subsystem

34 Using the HP E1459A Module Edge Detected Event DetectionThe HP E1459A can respond to two types of events: Edge Events (either negative edge, posit

Seite 43 - DIAGnostic:SYSReset:ENABle?

Using the HP E1459A Module 35Figure 2-1. HP E1459A Edge Event Detection Flowchart Unmask all 16 bits of Port.(Either Positive, Negative,or both.)Opt

Seite 44 - DISPlay:MONitor Subsystem

36 Using the HP E1459A Module Figure 2-2. HP E1459A Data Available Event Detection Flowchart Optionally, set theDebounce TimeEnable the DAV Detection

Seite 45 - DISP:MON:PORT:AUTO ON

Using the HP E1459A Module 37Example 3:Edge InterruptThis example repeatedly polls the Port 0 Port Summary Edge Detection Register to determine when

Seite 46 - DISP:MON?

38 Using the HP E1459A Module if (VI_SUCCESS > errStatus){printf("ERROR: viPrintf() returned 0x%x\n",errStatus);return errStatus;}/* Ena

Seite 47 - INPut Subsystem

Contents 3STATus:QUEStionable:CONDition? ... 66STATus:QUEStionable:ENABle <mask>

Seite 48 - Parameters

HP E1459A SCPI Command Reference 39Chapter 3HP E1459A SCPI Command ReferenceThe Standard Commands for Programmable Instruments (SCPI) commands descr

Seite 49 - Example INP2:DEB:TIME?

40 HP E1459A SCPI Command Reference For example, if the command syntax shows DISPlay, then DISP and DISPLAY are both acceptable forms. Other forms of

Seite 50 - MEASure Subsystem

HP E1459A SCPI Command Reference 41DIAGnostic:SYSReset SubsystemThe DIAGnostic:SYSReset Subsystem controls and monitors the Watchdog Timer. Refer to

Seite 51

42 HP E1459A SCPI Command Reference DIAGnostic:SYSReset:ENABle?Returns the state of the Watchdog Timer as either a (unsigned) 1, or 0.Parameters None

Seite 52 - MEMory Subsystem

HP E1459A SCPI Command Reference 43DISPlay:MONitor SubsystemThe DISPlay:MONitor subsystem turns on the monitor mode. Parameters related to the state

Seite 53 - SENSe Subsystem

44 HP E1459A SCPI Command Reference DISPlay:MONitor:PORT? [MINimum | MAXimum | DEFault]Returns the number of the current display Port as +0, +1, +2,

Seite 54

HP E1459A SCPI Command Reference 45DISPlay:MONitor[:STATe] <state>Turns the Display Mode on or off.ParametersComments • DISP:MON ON enables th

Seite 55

46 HP E1459A SCPI Command Reference INPut SubsystemThe INPut Subsystem configures the input de-bounce circuitry and specifies the input clock source.

Seite 56

HP E1459A SCPI Command Reference 47INPutn:CLOCk[:SOURce]?Returns the programmed value of the input clock source for Port n.ParametersComments • The

Seite 57

48 HP E1459A SCPI Command Reference INPutn:DEBounce:TIME? [MINimum | MAXimum | DEFault]Returns the current debounce time for Port n as a floating poi

Seite 58

4 ContentsArtisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Seite 59 - Parameters None

HP E1459A SCPI Command Reference 49MEASure SubsystemThe MEASure commands are used for the Isolated Digital Input part of the HP E1459A. These comman

Seite 60 - [SENSe:]EVENt:PSUMmary:EDGE?

50 HP E1459A SCPI Command Reference MEASure:DIGital:DATAn[:type]:BITm?Returns the value of BIT m of the data for the specified Port n as a signed int

Seite 61 - STATus Subsystem

HP E1459A SCPI Command Reference 51MEMory SubsystemThis command accesses the SCPI memory subsystem.MEMory:DELete:MACRo <name>Deletes the MACRO

Seite 62

52 HP E1459A SCPI Command Reference SENSe SubsystemThe SENSe Subsystem configures Event Detection in the HP E1459A Module. The HP E1459A has an event

Seite 63 - Example STAT:OPER:ENAB 0xFFFF

HP E1459A SCPI Command Reference 53[SENSe:]EVENt:PORTn:DAVailable:ENABle <state>Enables a Data Available interrupt to occur when new data is l

Seite 64

54 HP E1459A SCPI Command Reference [SENSe:]EVENt:PORTn:EDGE?Returns the status of the Edge Detect Event for Port n as either a a (unsigned) 0 or a 1

Seite 65

HP E1459A SCPI Command Reference 55[SENSe:]EVENt:PORTn:EDGE:ENABle?Returns the state of the Edge Event Enable for Port n as a (unsigned) 0 or a 1.Pa

Seite 66

56 HP E1459A SCPI Command Reference [SENSe:]EVENt:PORTn:NEDGe:ENABle <mask>Sets the Negative Edge Detection Mask for Port n.ParametersComments

Seite 67

HP E1459A SCPI Command Reference 57[SENSe:]EVENt:PORTn:PEDGe?Returns the value of the Positive Edge Detect Register for all 16 bits of Port n.Parame

Seite 68

58 HP E1459A SCPI Command Reference [SENSe:]EVENt:PORTn:PEDGe:ENABle?Returns the decimal value of the Positive Edge Detection Mask as a 16 bit intege

Seite 69 - SYSTem Subsystem

5CertificationHewlett-Packard Company certifies that this product met its published specifications at the time of shipment from the factory. Hewlet

Seite 70 - Example SYST:ERR?

HP E1459A SCPI Command Reference 59[SENSe:]EVENt:PSUMmary:EDGE?Returns the status of the edge events for ALL ports. Parameters NoneComments • The va

Seite 71 - IEEE 488.2 Common Commands

60 HP E1459A SCPI Command Reference STATus SubsystemThe STATus subsystem controls the SCPI-defined Operation and Questionable Status registers, Stand

Seite 72 - Command Quick Reference

HP E1459A SCPI Command Reference 61Figure 3-1. HP E1459A Status System Register DiagramArtisan Technology Group - Quality Instrumentation ... Guaran

Seite 73

62 HP E1459A SCPI Command Reference STATus:OPERation:CONDition?Returns the value of the Operation Status Condition Register as a signed 16 bit intege

Seite 74 - HP E1459A Specifications

HP E1459A SCPI Command Reference 63STATus:OPERation:ENABle?Returns the value of the OPERation Status Enable Register as a signed 16 bit integer.Para

Seite 75 - 74 HP E1459A Specifications

64 HP E1459A SCPI Command Reference STATus:OPERation:PSUMmary:ENABle <mask>Sets the value of the OPERation Status Port Summary Enable Register.

Seite 76 - Overview

HP E1459A SCPI Command Reference 65STATus:OPERation:PSUMmary[:EVENt]?Returns the value of the Operation Status Port Summary Event Register as a sign

Seite 77 - Addressing the Registers

66 HP E1459A SCPI Command Reference STATus:QUEStionable:CONDition?Always returns a 0. Note The Questionable Status Condition, Event, and Enable regis

Seite 78 - Register Definitions

HP E1459A SCPI Command Reference 67STATus:QUEStionable:ENABle?Returns the value of the QUEStionable Status Enable Register as a signed 16 bit intege

Seite 79

68 HP E1459A SCPI Command Reference SYSTem SubsystemThe SYSTem Subsystem returns module-specific information. This information includes module type a

Seite 80

6 Safety SymbolsInstruction manual symbol affixed to product. Indicates that the user must refer to the manual for specific WARNING or CAUTION inform

Seite 81 - Data Available

HP E1459A SCPI Command Reference 69SYSTem:ERRor?Queries the error register for the error value and string to identify the error. The errors are held

Seite 82 - Port 0/2

70 HP E1459A SCPI Command Reference IEEE 488.2 Common CommandsThe following table lists the IEEE 488.2 Common Commands listed by functional group tha

Seite 83 - Read Always Returns FFF

HP E1459A SCPI Command Reference 71Command Quick ReferenceCommand Subsystem Description See AlsoDIAG:SYSR:STAT?:ENAB <state>:ENAB?Returns the

Seite 84 - Detect Register Port

72 HP E1459A SCPI Command Reference Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Seite 85

HP E1459A Specifications 73Appendix AHP E1459A SpecificationsMax Input Voltage:Between High and Low terminal of Each Channel: 60V DC.Between Channel

Seite 86 - Port1/ Port 2 and

74 HP E1459A Specifications Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Seite 87 - Port 1/3

HP E1459A Register Definitions 75Appendix BHP E1459A Register DefinitionsOverviewThe HP E1459A Isolated Digital Input/Interrupt module is a register

Seite 88 - Register Port 1/3

76 HP E1459A Register Definitions Addressing the RegistersTo read or write to specific registers you must address a particular register within a modu

Seite 89

HP E1459A Register Definitions 77For example, for the HP 75000 Series C Mainframe with an HP E1406 Command Module, VXI A16 address space starts at 1

Seite 90

78 HP E1459A Register Definitions Manufacturer IDRegisterID register (base = 00h) is a read only register. For the Isolated Digital Input/Interrupt,

Seite 91

7Jim White, QA ManagerEuropean contact: Your local Hewlett-Packard Sales and Service Office or Hewlett-Packard GmbH, Depart-ment HQ-TRE, Herrenberg

Seite 92 - Programming Examples

HP E1459A Register Definitions 79READE IRQ = When "1" it indicates that an INTRX line has transitioned from being asserted.D IRQ = When &q

Seite 93 - Detection Examples

80 HP E1459A Register Definitions Bit 14 is the MODID bit. When a "0" is returned in bit 14 then the module has been selected with a high s

Seite 94

HP E1459A Register Definitions 81Watchdog TimerControl/StatusRegisterThe Watchdog Timer Control/Status Register (base + 0Ah) can be read or written.

Seite 95 - ! get data register port 1

82 HP E1459A Register Definitions the bit in the Data Available Status Register will also be unasserted. An interrupt will only occur on the backpla

Seite 96

HP E1459A Register Definitions 83Channel DataRegister Port 0/2The Channel Data Register for Port 0/2 (base + 12h) is read only. This register retur

Seite 97

84 HP E1459A Register Definitions Negative EdgeDetect Register Port0/2The Negative Edge Detect Register for Port 0/2 (base + 16h) is read only. This

Seite 98

HP E1459A Register Definitions 85Debounce ClockRegister Port 0 andPort1/ Port 2 andPort 3The Debounce Clock Register (base + 1Eh) can be read or wri

Seite 99

86 HP E1459A Register Definitions Command RegisterPort 1/3The Command Register for Port 1/3 (base + 20h) can be read or written. It contains three b

Seite 100 - DATA REGISTERS for each port

HP E1459A Register Definitions 87should only be enabled when in external trigger mode. When set to "0" the DAV1/3 line cannot cause an int

Seite 101

88 HP E1459A Register Definitions Positive EdgeDetect Register Port1/3The Positive Edge Detect Register for Port 1/3 (base + 24h) is read only. If b

Seite 102

8 Notes:Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Seite 103

HP E1459A Register Definitions 89Negative MaskRegister Port 1/3The Negative Mask Register for Port 1/3 (base + 2Ah) can be read or written. If bit

Seite 104 - 1970 END

90 HP E1459A Register Definitions Register Value Bit Pattern (Hex) Clock Frequency Clock Period Debounce Time (4 - 4.5 Clock Periods)2 (or 0 ) De

Seite 105

HP E1459A Register Definitions 91Power On/Reset ConditionsA soft reset is generated when the reset bit in the control register is set active and the

Seite 106 - Error Messages

92 HP E1459A Register Definitions /* read and print the module’s Device Type Register */errStatus = viIn16(E1459,VI_A16_SPACE,0x02,&dt_reg);if

Seite 107 - 106 Error Messages

HP E1459A Register Definitions 93150 !160 REPEAT170 OUTPUT Vxi_address;"SYST:ERR?"180 ENTER Vxi_address;Error190 PRINT &quo

Seite 108 - Index 107

94 HP E1459A Register Definitions 620 OUTPUT Vxi_address;"VXI:WRITE 128,4,32" 630 !640 LOOP650 DISABLE INTR 7660 !6

Seite 109 - 108 Index

HP E1459A Register Definitions 951140 OUTPUT Vxi_address;"VXI:READ? 128,22" 1150 ENTER Vxi_address;B1160 PRINT "Wrd 0

Seite 110 - Index 109

96 HP E1459A Register Definitions 1650 OUTPUT Vxi_address;"DIAG:INT:ACT ON"1660 OUTPUT Vxi_address;"*OPC?"1670 ENTER Vxi_addre

Seite 111 - 110 Index

HP E1459A Register Definitions 97365 ! dav enable, ext clk, port 2370 OUTPUT Vxi_address;"VXI:WRITE 128,16,6" 375 ! mask o

Seite 112

98 HP E1459A Register Definitions 860 OUTPUT Vxi_address;"VXI:READ? 128,8" ! get dav status register870 ENTER Vxi_address;A880 !89