Seite 1 - HP ProLiant Network Adapter

HP ProLiant Network Adapter Software and Configuration Guide Part Number 441877-00J November 2008 (Nineth Edition)

Seite 2 - Intended audience

Installation 10 Installation Downloading the SoftPaq files 1. Go to the HP website (http://www.hp.com). 2. Click Software & Driver Downloads fr

Seite 3 - Contents

Configuration and diagnostics 11 Configuration and diagnostics Configuring adapters using operating system software The following sections describe

Seite 4 - Contents 4

Configuration and diagnostics 12 o Range = None; Magic Packet; Wake up Frame; Both • Flow Control. The Flow Control property allows the user to ena

Seite 5 - Overview

Configuration and diagnostics 13 system memory used by the driver. If too few receive descriptors are used, performance suffers. If too many receive

Seite 6 - Overview 6

Configuration and diagnostics 14 o 2500 Mb. To achieve speeds of 2.5 Gbps, update to the latest firmware and then set the link partner (switch or hu

Seite 7 - Windows 2008 drivers

Configuration and diagnostics 15 • IPv4 Checksum Offload. Describes whether the device enabled or disabled the calculation of IPv4 checksums. o Tx

Seite 8 - Windows 2003 x64 drivers

Configuration and diagnostics 16 • TCP Offload Engine (TOE). Enables the offloading of TCP connections to HP Multifunction Server Adapters. Microso

Seite 9 - Overview 9

Configuration and diagnostics 17 Parameter Options Description PDriver = Default = OFF Selections are: OFF, ON Allows driver to operate in persist

Seite 10 - Installation

Configuration and diagnostics 18 Parameter Options Description RxTicks= Default = 360 Min = 0, disabled Max = 5000000, 5 seconds Units are in m

Seite 11 - Server 2008 x64

Configuration and diagnostics 19 set Default Time Server Type = SINGLE set Bindery Context = O=LAN # WARNING!! file server name NOVELLSERVER51 # WA

Seite 12

© Copyright 2005, 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warr

Seite 13

Configuration and diagnostics 20 default to half-duplex. You must have an auto-negotiating switch/hub (an Nway switch) to get full-duplex support wi

Seite 14 - Server 2003 x64

Configuration and diagnostics 21 Where n = Ethernet_802.2, Ethernet_802.3, Ethernet_II, Ethernet_SNAP o Default = Ethernet_802.2 • POLL. This keyw

Seite 15

Configuration and diagnostics 22 o Syntax: commit [team=nnn] o Description: Sets a certain mode. Use after binding to base drivers with Team=nnn. •

Seite 16

Configuration and diagnostics 23 o Description: Changes probe retries check interval • PROBE_RETRY_COUNT o Syntax: probe_retry_count=nnn o Descri

Seite 17

Configuration and diagnostics 24 o Syntax: team=nnnn o Description: Identifies the team. nnnn=DecimalNumber. • TX_ECBS_TO_USE o Syntax: tx_ecbs_t

Seite 18

Configuration and diagnostics 25 o Address test: Writes each address with unique increment data. Reads back data to ensure data is correct. After fi

Seite 19

Configuration and diagnostics 26 • This tests both high and low priorities DMA. It moves data from host memory to adapter SRAM, verifies data, and

Seite 20

Configuration and diagnostics 27 • Invalid adapter device • Read only bit %s got changed after writing zero at offset 0x%X • Read only bit %s got

Seite 21

Configuration and diagnostics 28 • %d bad packets have been received • %c%d is an invalid Test • EEPROM checksum error • Error in reading WOL/PX

Seite 22

Configuration and diagnostics 29 • *1 Internal Use. Program will not generate this error. HP NC-Series Broadcom 10 GbE adapter diagnostics The eDi

Seite 23

Contents 3 Contents Overview...

Seite 24

Configuration and diagnostics 30 Options Description -wol <1|0>. Enable (1) / Disable(0) magic packet Wake-on-LAN option. -mba <1|0> E

Seite 25

Configuration and diagnostics 31 The following return codes are the available upon exit of the eDiag utility. The return codes are backward compatib

Seite 26

Configuration and diagnostics 32 Return Code Value Description ERR_PRG_MFW 61 Fail to program IPMI/UMP firmware ERR_PRG_MBA 62 Fail to program

Seite 27

Configuration and diagnostics 33 Return Code Value Description ERR_REG_TCM_TEST 118 TCM Register test fails ERR_REG_TM_TEST 119 TM Register te

Seite 28

Configuration and diagnostics 34 Return Code Value Description ERR_MEM_XSDM_TEST 157 XSDM Memory test fails ERR_MEM_XSEM_TEST 158 XSEM Memory

Seite 29

Configuration and diagnostics 35 Return Code Value Description ERR_PRG_IB 195 Fail to program iSCSI boot image HP NC-Series Broadcom Multifunc

Seite 30 - Return Codes

Configuration and diagnostics 36 • B5. CP scratchpad • B6. MCP scratchpad • B7. TAS header buffer • B8. TAS payload buffer • B9. RBUF via GRC

Seite 31

Configuration and diagnostics 37 This tests the internal DMA engine by performing both DMA reads and writes at various location and various sizes. C

Seite 32

Configuration and diagnostics 38 The ccfwupg1.bat command upgrades the Boot Code and Option ROM firmware image on the following c-Class Multifunctio

Seite 33

Configuration and diagnostics 39 Using the -S option the user can optionally select the non-interactive mode, which causes the firmware to automatic

Seite 34

Contents 4

Seite 35

Configuration and diagnostics 40 Property Parameter Max Jumbo Buffers Specifies the number of 8K (jumbo) buffers for receive, in addition to the st

Seite 36

Configuration and diagnostics 41 Property Parameter Vlan Id Sets the VLAN ID for this interface (also exposed through the standard OID). QoS Packet

Seite 37 - BladeSystem

Configuration and diagnostics 42 HP NC-Series NetXen Online Firmware Upgrade Utility The HP NC-Series NetXen Online Firmware Upgrade Utility for Win

Seite 38 - Utility

Configuration and diagnostics 43 Command Definition Description -a, --all Update all of firmware Updates the flash memory using appropriate romimag

Seite 39 - HP NC-Series NetXen adapters

Configuration and diagnostics 44 1. Execute the following command to enable PXE functionality: nxflash -i eth<#> --opt-rom-on 2. Execute the

Seite 40

Configuration and diagnostics 45 o Default = Auto Detect o Range = Auto Detect; Force Master Mode; Force Slave Mode • Interrupt moderation. If ena

Seite 41

Configuration and diagnostics 46 o Range = Disabled; Enabled • Priority and VLAN. Enables or disables the ability to insert or remove the 802.1q ta

Seite 42

Configuration and diagnostics 47 • Wake On Settings. Available only when Enable PME is enabled. Allows you to choose what types of packets will cau

Seite 43

Configuration and diagnostics 48 • Number of Receive Descriptors. Specifies the number of buffers used by the driver when copying data to the proto

Seite 44 - HP NC-Series Intel Adapters

Configuration and diagnostics 49 o Range = Disabled; Enabled; Hardware Default; No Action (NC110x, NC360x, NC364x = OS Controlled, Disabled, Enabled

Seite 45

Overview 5 Overview Supported adapters and operating systems The following is a list of HP NC-Series adapters that are supported on HP ProLiant serve

Seite 46

Configuration and diagnostics 50 • Number of test passes—This option determines how many times a test runs. While the test is running, the informat

Seite 47

Configuration and diagnostics 51 Adapter properties and configurations on Netware A network device driver must be installed before the Gigabit Ether

Seite 48

Configuration and diagnostics 52 Parameter Options Description TxDescriptors = Default = 200 Recommended Min = 100 Max = 512 Min = 1 when used wit

Seite 49

Configuration and diagnostics 53 three times the minimum packet receive buffers. Typically one MB of RAM is required per 1000 receive buffers. In t

Seite 50

Configuration and diagnostics 54 LOAD Q57 SLOT=2 FRAME=Ethernet_SNAP NAME=Q57_1_ESP BIND IPX Q57_1_ESP NET=477A35BD LOAD Q57 SLOT=2 FRAME=Ethernet_I

Seite 51

Configuration and diagnostics 55 o Default = auto-negotiate o Examples: 100 Mbps full-duplex FORCEDUPLEX=2 SPEED=100 10 Mbps full-duplex FORCEDUPLE

Seite 52

Configuration and diagnostics 56 0—Driver operates in normal mode 1—Driver operates to reduce the number of spurious interrupts o Default = 1 N

Seite 53

Configuration and diagnostics 57 • LBN o Syntax: Reset LBN=nnn o Example: cpqans reset lbn=nnn o Description: Resets the logical board number (

Seite 54

Configuration and diagnostics 58 o Syntax: probes=[BROADCAST|MULTICAST] o Description: Changes probes addressing • RECOMMIT o Syntax: recommit [t

Seite 55

Configuration and diagnostics 59 • Compliance with the Pre-boot eXecution Environment (PXE) Version 2.1 Specification • Remote Program Load (RPL)

Seite 56

Overview 6 • HP NC325i PCI Express Dual Port Gigabit Server Adapter • HP NC326i PCI Express Dual Port Gigabit Server Adapter • HP NC370i PCI-X Mul

Seite 57

Configuration and diagnostics 60 within the allowed number of seconds, reboot the computer to try again. If you select a Setup Menu Wait Time settin

Seite 58 - Boot Agent

Configuration and diagnostics 61 Configuration settings Possible values Description Show Setup Prompt • Enabled • Disabled Controls whether or no

Seite 59

Configuration and diagnostics 62 Use IBAUtil to enable or disable WOL or Boot Agent features. To obtain this utility download the HP ProLiant Networ

Seite 60

Configuration and diagnostics 63 Parameter Description -UP, -UPGRADE or -INSTALL -UP: Programs an Intel Boot Agent image into the FLASH on the sel

Seite 61

Configuration and diagnostics 64 • 1–Operator termination • 2–Invalid adapter • 3–Bad command line parameter • 4–EEPROM checksum failure • 5–E

Seite 62

Configuration and diagnostics 65 attempt to remote boot. If this error persists, try updating your system's BIOS to the most-recent version. Co

Seite 63 - • 0–Success

Configuration and diagnostics 66 The adapter does not detect link. Be sure that the cable is good and is attached to a working hub or switch. The li

Seite 64

Configuration and diagnostics 67 After the Boot Agent product has finished its sole task (remote booting), it no longer has any effect on the client

Seite 65

Configuration and diagnostics 68 Anytime the Configuration Setup Menu is displayed (refer to the "Configuring the Boot Agent in a pre-boot PXE

Seite 66

Configuration and diagnostics 69 recommended selection is Off and it is the default setting. To disable Flow Control, select Off from the Value list

Seite 67

Overview 7 • NetWare Open Enterprise Server Linux 32 • Red Hat Enterprise Linux 5 • Red Hat Enterprise Linux 4 • Red Hat Enterprise Linux 3 • S

Seite 68

Configuration and diagnostics 70 To enable the Gigabit Ethernet adapter to function correctly, you need to install the latest support pack files. Th

Seite 69

Configuration and diagnostics 71 Parameter Options Description Slot = n Identifies the slot number for the specific adapter currently being confi

Seite 70

Configuration and diagnostics 72 • set minimum packet receive buffers = 10000 • set maximum physical receive packet size = 2048 Verifying or modif

Seite 71

Configuration and diagnostics 73 To remove the drivers from the Autoexec.ncf, locate the LOAD and BIND command lines associated with the driver and

Seite 72

Configuration and diagnostics 74 • SPEED. This keyword specifies the speed the driver uses. If you do not use this parameter, the driver automatica

Seite 73

Configuration and diagnostics 75 Where n = 0 or 1 0—Does not offload Rx Checksum verification to the adapter 1—Offloads Rx Checksum verification to

Seite 74

Configuration and diagnostics 76 o Syntax: mode=[NFT | ALB | FEC | GEC | 802.3AD] • NAME o Syntax: name=[any unique name] o Description: Sets a u

Seite 75

Configuration and diagnostics 77 o Syntax: RemoveVlanID=nnn o Description: Removes the selected VLAN • RESET o Syntax: RESET LBN=nnn o Descript

Seite 76

Technical support 78 Technical support Before you contact HP Be sure to have the following information available before you call HP: • Technical su

Seite 77

Technical support 79 • For downloadable support software for HP Digital Networking Products, Hubs, Integrated Access Devices, Modems and ISDN, Adap

Seite 78 - Technical support

Overview 8 • N1G60i32.sys for NC310xx, NC340x, NC61xx, and NC71xx server adapters • Q57ND60X.sys for NC105x, NC107x, NC10xx, NC150x, NC32xx, NC10x

Seite 79 - Technical support 79

Acronyms and abbreviations 80 Acronyms and abbreviations BIOS Basic Input/Output System DHCP Dynamic Host Configuration Protocol IPL initial progr

Seite 80 - Acronyms and abbreviations

Acronyms and abbreviations 81 UNDI Universal Network Driver Interface

Seite 81

Index 82 B Boot Agent 58 D driver and software information 7 F firmware upgrade 38, 42 I installation 10 P properties 14, 68 PXE configurat

Seite 82 - Index 82

Overview 9 • NXP2NC64.sys for all NC51xx 10GbE server adapters • BXND52a.sys for all NC532x 10GbE server adapters Components for these drive rs are

Kommentare zu diesen Handbüchern

Keine Kommentare