Seitenansicht 56
Hardware options installation 57
4.
Use the power cord management clip to secure the cord and form a service loop.
5. Connect the power cord to the AC power source.
6. Be sure that the power supply LED is green ("Rear panel LEDs" on page 12).
IMPORTANT: For maximum server availability, be sure that the two power supplies are powered
by separate AC power sources.
Hot-plug SAS hard drive options
When adding hard drives to the server, observe the following general guidelines:
The system automatically sets all device numbers.
If only one hard drive is used, install it in the bay with the lowest device number.
Drives should be the same capacity to provide the greatest storage space efficiency when drives are
grouped together into the same drive array.
Installing a hot-plug SAS hard drive
1. Remove the SAS hard drive blank.