Component identification 8
Front panel LEDs and buttons
Item Description Status
1
System power LED Green = Power on
Flashing green = Waiting for power due to group power capping
Amber = System in standby, but power still applied
Off = Power cord not attached or power supply failure
2
Health LED Green = Normal
Amber = System degraded. To identify the component in a degraded
state, see the system board LEDs (on page 13).
Red = System critical. To identify the component in a critical state, see
the system board LEDs (on page 13).
Off = Normal (when in standby mode)
3
Power cap LED Green = Power cap configured
Flashing amber = Power cap exceeded
Off = Server in standby or power cap disabled
4
NIC 1 activity LED Green = Network link
Flashing = Network link and activity
Off = No link to network. If power is off, view status on the rear panel
RJ45 LEDs ("Rear panel LEDs and buttons" on page 10).
5
NIC 2 activity LED Green = Network link
Flashing = Network link and activity
Off = No link to network. If power is off, view status on the rear panel
RJ45 LEDs ("Rear panel LEDs and buttons" on page 10).
6
UID LED Blue = Activated
Flashing = System managed remotely
Off = Deactivated