Hp ProLiant ML310 G5 Server Bedienungsanleitung Seite 30

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 99
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 29
Hardware options installation 30
Slot 1A Slot 2B Slot 3A Slot 4B Total memory Mode
2 GB — — — 2 GB Single-bank
2 GB 2 GB 4 GB Single-bank interleaved
2 GB 2 GB 2 GB 6 GB Dual-bank asymmetric
2 GB 2 GB 2 GB 2 GB 8 GB Dual-bank interleaved
Installing DIMMs
1. Power down the server (on page 17).
2. Unlock the bezel (on page 18).
3. Remove the access panel (on page 19).
4. Open the DIMM slot latches.
5. Install the DIMM.
6. Install the access panel (on page 19).
7. Lock the bezel.
8. Power up the server (on page 17).
Hard drives
The server supports non-hot-plug SATA hard drives.
Optional hot-plug SATA or SAS hard drives may be supported in select configurations ("SAS controller"
on page 42).
The SATA RAID feature supports the following configurations:
Two RAID volumes with two hard drives per volume
One RAID volume with four hard drives
Seitenansicht 29