HP ProLiant 750 W Power Supply
Specification Value
Input requirements
Rated input voltage 100V to 120V AC
200V to 240V AC
Rated input frequency 50Hz to 60Hz
Rated input current 8.9A at 100V AC
4.3A at 200V AC
Rated input power 857 W at 100V AC input
824 W at 200V AC input
BTUs per hour 2925 at 100V AC input
2812 at 200V AC input
Power supply output
Rated steady-state power 750 W at 100V to 120V AC
input
750 W at 200V to 240V AC
input
Rated peak power 750 W at 100V to 120V AC
input
750 W at 200V to 240V AC
input
HP ProLiant 1200 W Power Supply
Specification Value
Input requirements
Rated input voltage 100V to 120V AC
200V to 240V AC
Rated input frequency 50 Hz to 60 Hz
Rated input current 10A at 100V AC
4.9A at 200V AC
Rated input power 930 W at 100V AC input
1348 W at 200V AC input
BTUs per hour 3530 at 120V AC input
4600 at 200V to 240V AC
input
Power supply output
Rated steady-state power 800 W at 100V AC input
900 W at 120V AC input
1200 W at 200V to 240V AC
input