Hp e-Commerce Server Accelerator sa7120 Bedienungsanleitung Seite 142

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 192
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 141
C H A P T E R 9 HP e-Commerce Server Accelerator SA7100/SA7120 User Guide
132
7
Error message:
Server/Network
media mismatch
Server and
network ports
have
autonegotiated to
different media
settings.
Use the status command to determine
the media settings:
HP SA7120> status
.
.
Network port 100baseTX Full
Duplex
Server port 10baseT, Half
Duplex
Then use the nic command to force
common media attributes, e.g.:
HP SA7120> nic
1 - auto
2 - 10baseT, half duplex
3 - 10baseT, full duplex
4 - 100baseTX, half duplex
5 - 100baseTX, full duplex
Select media type [1] 2
In the example above, 2 is the correct
choice because the setting must reflect
the least common denominator of
both media speed and duplex attribute,
i.e., the server port is determinative
because it has both the lower speed
and lower (half) duplex attribute.
Item Symptom Probable
Cause
Remedy
Seitenansicht 141