Hp NC550SFP Dual Port 10GbE Server Adapter Bedienungsanleitung Seite 35

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 43
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 34
Configuring iSCSI boot support 35
e.
Select the same LUN you chose for your initial boot LUN, then press F3 to set it to bootable.
10. After Linux boots up, the MPIO installs drivers on the second path and then prompts you to reboot.
Reboot the system.
Windows Server
1. Log into HP NC-Series ServerEngines iSCSISelect by pressing Ctrl+S when prompted.
2. Log into a target from one HBA and configure it for boot by following the steps in "Setting up a
basic iSCSI boot configuration (on page 30)."
If iSCSISelect is configured properly, you will get an indication during boot time that the iSCSI disk
was successfully connected.
Only one instance of the boot LUN must be visible to the server during the installation. The
installation might fail if multiple instances of the boot LUN are available to the server.
It is recommended that the Spanning Tree Protocol be disabled on any ports that are connected to
Windows Server 2008 hosts booting using iSCSI. The Spanning Tree Protocol is used to calculate
the best path between switches where there are multiple switches and multiple paths through the
network.
3. Install a Windows Server operating system over the iSCSI LUN.
4. Once Windows Server is installed, install MPIO software (such as Microsoft iSCSI Initiator), and
reboot the system.
5. After rebooting, ensure that the boot LUN is detected by the MPIO driver. This can be done by
either:
o Looking at the driver name for the disk device from Device Manager
o Using Microsoft iSCSI Initiator to navigate to:
MS iSCSI Initiator GUI -> Boot tgt-> Boot LUN -> MPIO capable
6. Reboot your system and log into iSCSISelect by pressing Ctrl+S when prompted.
7. You can now add an additional boot path with iSCSISelect. To add an additional boot path to the
same iSCSI LUN, do the following:
a. Follow the steps in "Setting up a basic iSCSI boot configuration (on page 30)" to set up your
second path.
b. When you get to the Add/Ping iSCSI Target menu, make sure you set an ISID Qualifier before
adding your target.
c. After you have logged into the target, from the iSCSI Target Configuration menu, set the Boot
Target option for the second target to Yes.
d. Press F7 to display the LUNs behind the target.
e. Select the same LUN you chose for your initial boot LUN, and then press F3 to set it to bootable.
8. After Windows Server boots up, the MPIO will install drivers on the second path and you are
prompted to reboot. Reboot the system.
ESX Server 3.5
1. Log into iSCSISelect by pressing Ctrl+S when prompted.
2. Use iSCSISelect to log into a target from one HBA and configure it for boot.
Seitenansicht 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 41 42 43

Kommentare zu diesen Handbüchern

Keine Kommentare