1-4 instant Capacity on Demand Notes for Installation and Use
*********************************************************************
2.0 Installing iCoD
The iCoD software must be installed after Tru64 UNIX has been installed.
Mail notifications are sent to the root account when iCAP is installed,
initialized, or removed from the system.
2.1 Restrictions
• This version of iCAP is supported on Tru64 UNIX versions 5.1A and
5.1B.
• iCAP is supported only on ES47, ES80, GS80, GS160, GS320, and
GS1280 systems.
• iCAP software and associated SMP licenses must be installed on all
systems that have iCAP CPUs.
2.2 Retrieving iCAP Software from the instant Capacity on
Demand CD-ROM
1. Log in as root or use the su(1) command to gain superuser privileges.
2. Use the mkdir(1) command to create the directory in which you want to
copy the iCAP kit:
/sbin/mkdir directory_name
For example, create a directory called iCAP under /var/tmp:
/sbin/mkdir /var/tmp/cod
3. Insert the instant Capacity on Demand CD-ROM into the drive.
4. You must determine the CD-ROM device name to mount the instant
Capacity on Demand CD-ROM. Enter the following command to find the
read-only CD-ROM device:
# file /dev/rrz*c | grep -E 'RRD|CD'
/dev/rrz4c: character special (8/4098) SCSI #0 RRD45 \
disk #32 (SCSI ID #4) (SCSI LUN #0) offline
/dev/rrz4c: character special (8/2) EIDE #0 CD-ROM X \
disk #0 (SCSI ID #0) (SCSI LUN #0) offline