ACC X.25 Data Analyzer User’s GuideEdition 1HP 9000 NetworkingManufacturing Part Number : Z7345-90004E0204© Copyright 2004 Hewlett-Packard Company.

Seite 2

Contents10Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36runc . . . .

Seite 3 - Legal Notices

Chapter 1 111 OverviewThis chapter provides an overview of the data analyzer, a description of data analyzer features, and data analyzer requirements.

Seite 4

OverviewData Analyzer OverviewChapter 112Data Analyzer OverviewThe data analyzer is supplied with the ACC Base System product. It is a software based

Seite 5

OverviewData Analyzer OverviewChapter 1 13Figure 1-1 Overview of ACC based Data AnalyzerCapture / FilterDaemonData captureFile(s)Commands toFilter Con

Seite 6

OverviewData Analyzer OverviewChapter 114Only one copy of the capture daemon runs in each HP 9000 system. It handles all analyzer sessions. The contro

Seite 7 - Manual Organization

OverviewData Analyzer FeaturesChapter 1 15Data Analyzer FeaturesThe following list summarizes the features offered by the ACC X.25 data analyzer. • Si

Seite 8 - Related Documentation

OverviewData Analyzer RequirementsChapter 116Data Analyzer RequirementsThe data analyzer requires that the ACC Base System product has been installed,

Seite 9

Chapter 2 172 Installing the Data Analyzer

Seite 10 - Contents

Installing the Data AnalyzerInstalling the Analyzer SoftwareChapter 218Installing the Analyzer SoftwareThe data analyzer software is provided with the

Seite 11 - 1 Overview

Installing the Data AnalyzerInstalling the Analyzer SoftwareChapter 2 19NOTE swremove will fail if any ACC daemon is still active. Terminate any activ

Seite 13 - 8 port PCI &

Installing the Data AnalyzerInstalling the Analyzer SoftwareChapter 220The “Install (analysis)” window allows you to track summary progress of the ins

Seite 14

Installing the Data AnalyzerInstalling the Analyzer SoftwareChapter 2 21However, the prompt Display> indicates that pdisplay is ready for interacti

Seite 15 - Data Analyzer Features

Installing the Data AnalyzerInstalling the Analyzer SoftwareChapter 222When complete, the Display> prompt reappears. More commands can be entered n

Seite 16 - Data Analyzer Requirements

Installing the Data AnalyzerConfiguring the AnalyzerChapter 2 23Configuring the AnalyzerThe analyzer can be configured dynamically, as needed, and thi

Seite 17 - Chapter 2 17

Installing the Data AnalyzerConfiguring the AnalyzerChapter 224For example, you can set-up and run the analyzer on the first two ports of the first 8-

Seite 18 - Software Removal

Chapter 3 253 Data Analyzer CommandsThis chapter describes each of the pdisplay program commands. Each command is described in detail and followed by

Seite 19 - Software Installation

Data Analyzer CommandsDetailed Command DescriptionsChapter 326Detailed Command DescriptionsThe following sections describes each of the pdisplay progr

Seite 20 - Verifying Installation

Data Analyzer CommandsdisplayChapter 3 27displayThe display command displays the contents of the capture file (.eve) to the screen or to standard out.

Seite 21

Data Analyzer CommandsdisplayChapter 328ExampleThe following example demonstrates usage for this command.NOTE See “Typical X.25 and Data Analyzer Sess

Seite 22 - Exit Program

Data Analyzer CommandsdisplayChapter 3 29 X.25:INCOMING CALL mod8 LCI 1 Called addr

Seite 23

3Legal Notices The information in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to th

Seite 24 - Display> runc 0 0

Data Analyzer CommandsexitChapter 330exitThe exit command is used to exit from pdisplay. Note that when pdisplay is exited, any analyzer sessions that

Seite 25

Data Analyzer CommandshelpChapter 3 31helphelp displays help information on available commands, and details on each of the commands.Format?? [command]

Seite 26 - Detailed Command Descriptions

Data Analyzer CommandsoptionsChapter 332optionsThe options command shows or sets the display options.Formatoptions [set <string>]or:options [sho

Seite 27 - Description

Data Analyzer CommandsoptionsChapter 3 33z/Z Turn off/ON Level 4 raw display (s/S option gives raw mode).To change the option setting use the set par

Seite 28

Data Analyzer CommandsprotocolChapter 334protocolThe protocol command Selects Level 2/Level 3 protocols for display of analyzer trace data.Formatproto

Seite 29 - Chapter 3 29

Data Analyzer CommandsrunChapter 3 35runThe run command starts the analyzer on a specified pair of ZLUs.Formatrun ZLU [-n filename] [-s filesize] [-l

Seite 30

Data Analyzer CommandsrunChapter 336-p Specify level 2 or level 3 protocol for analysis and trace display. See the protocol command for specific deta

Seite 31 - Examples

Data Analyzer CommandsruncChapter 3 37runcThe command runc creates a pair of analyzer ZLUs using the specified interface card, port and subchannel, an

Seite 32

Data Analyzer CommandsshowChapter 338showThis command displays all the ZLUs configured in the ACC Mux system. FormatshowDescriptionThe show command sh

Seite 33 - Default display options set

Data Analyzer CommandsshowChapter 3 39AZLU This is the partner ZLU, which should also appear in the display. The partner ZLU must be a different type

Seite 34

4This software is based in part on the Fourth Berkeley Software Distribution under license from the Regents of the University of California. ©copyrigh

Seite 35

Data Analyzer CommandsshutdownChapter 340shutdownThe shutdown command shuts down the pcapture program.FormatshutdownDescriptionThis command is used to

Seite 36 - Display> run 19

Data Analyzer CommandsstopChapter 3 41stopThe stop command stops the analyzer on a specified pair of ZLUs.:Formatstop ZLUDescriptionThis command stops

Seite 37

Data Analyzer CommandsstopdChapter 342stopdThe stopd command stops the analyzer and deletes the analyzer ZLUs in use provided that they were dynamical

Seite 38

Appendix A 43A Network Configuration

Seite 39

Network ConfigurationSetting Up the Network Configuration FileAppendix A44Setting Up the Network Configuration File The first step is to configure the

Seite 40

Network ConfigurationSetting Up the Network Configuration FileAppendix A 45Port DefinitionsEach port on each multiplexer card to be used for the Data

Seite 41

Network ConfigurationSetting Up the Network Configuration FileAppendix A46Follow the steps below to configure the ZLUs, refer to the examples above fo

Seite 42

Network ConfigurationSetting Up the Network Configuration FileAppendix A 47 $ ttgen -o /opt/acc/cfg/x25an_sample.answ \ /opt/acc/cfg/x2

Seite 43 - A Network Configuration

Network ConfigurationSetting Up the Network Configuration FileAppendix A48Pcapture runs as a daemon and reports its errors to the ACC Mux message file

Seite 44 - Mux Firmware Download File

Network ConfigurationSetting Up the Network Configuration FileAppendix A 49 Exit program $This method may be used to save the display output from a

Seite 45 - ZLU Definitions

5Publishing HistoryThe manual publishing date and part number indicate its current edition. The publishing date will change when a new edition is pu

Seite 46

Network ConfigurationSample Network Configuration FileAppendix A50Sample Network Configuration FileThe sample network configuration file (ttgen config

Seite 47 - $ pcapture

Network ConfigurationSample Network Configuration FileAppendix A 51Terminal-Definition Term 0017 0:0 X25.LAPB 0009H 43EAH 10 0 0 0 0 ”Leve

Seite 48

Network ConfigurationSample Network Configuration FileAppendix A52

Seite 49 - Exit program

Appendix B 53B Typical X.25 and Data Analyzer Sessions

Seite 50

Typical X.25 and Data Analyzer SessionsIntroductionAppendix B54IntroductionThis section provides the results of actual Data Analyzer sessions that wer

Seite 52 - Appendix A52

7PrefaceThis manual describes the Data Analyzer accessory product for the ACC family of multiplexers.Manual OrganizationThis manual contains the fol

Seite 53 - Sessions

8Related DocumentationThe documentation available for the Multiprotocol ACC family of products includes the following hardware and software manuals:Ha

Seite 54 - Introduction

9Contents1. OverviewData Analyzer Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Data A

Kommentare zu diesen Handbüchern

Keine Kommentare