Table 86 SSB codes that are returned by raidcom delete ssid command (continued)
raidcom delete ssid
DescriptionError codeExecuting/
Async
Error message
SSB2SSB1
An internal error occurred.00EF2ED6ExecutingCMDRJE
Call HP Technical Support.
The SSID is invalid.33002ED6ExecutingCMDRJE
The specified parameter is invalid. Check the HP XP7 RAID
Manager Reference Guide.
30022EF3ExecutingCMDRJE
Table 87 SSB codes that are returned by raidcom add thp_pool command
raidcom add thp_pool
DescriptionError codeExecuting/
Async
Error message
SSB2SSB1
LDEV number is out of rage.00002E00AsyncGet Command Status
The value of pool ID is out of range.60002E00ExecutingCMDRJE
The type of pool is invalid.60012E00ExecutingCMDRJE
The maximum reserve ratio of V-VOL is out of range.60022E00ExecutingCMDRJE
The threshold of the specified High water mark is out of range.60092E00ExecutingCMDRJE
The operation cannot be done because the specified threshold
of Warning is larger than the threshold of the specified High
water mark.
600A2E00ExecutingCMDRJE
The specified LDEV is in the state of blocked.00092E10AsyncGet Command Status
The operation cannot be done because a SATA-E drive in the
state of quick formatting is in the specified LDEV.
000C2E10AsyncGet Command Status
The specified LDEV is in the state of blocked, or not installed.00112E10ExecutingCMDRJE
The pool cannot be created because there are not enough
resources (VDEV) depending on cache management devices.
01022E10AsyncGet Command Status
The operation cannot be performed because the pool volume
is being deleted.
600D2E10AsyncGet Command Status
The specified operation is not supported in the current microcode
version.
80022E10AsyncGet Command Status
The pool is not in the status where the pool volume can be
added.
60032E11Executing
/Async
CMDRJE
Get Command Status
The operation cannot be done because the power supply is
switched off.
80032E11AsyncGet Command Status
The command cannot be accepted. After a while, execute the
same command.
94002E11ExecutingCMDRJE
The specified LDEV is not installed.00002E20AsyncGet Command Status
The operation cannot be performed because the memory
capacity of the shared memory (SM) is insufficient.
81032E21AsyncGet Command Status
The operation cannot be performed because the shared memory
(SM) is not initialized.
81062E21AsyncGet Command Status