Hp XP RAID Manager Software Bedienungsanleitung Seite 26

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 37
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 25
Table 14 SNMP failure trap reference codes (continued)
Alert levelDescriptionTrap reference code
SIM13SIM23SIM22
MODERATEProcessorDMA blockxy83CF
MODERATEProcessorSynchronized DMA blockxx87CF
MODERATEProcessorLR blockxx88CF
MODERATEProcessorAll DMA blockxx89CF
MODERATEProcessorMF DMA blockxxBxCF
MODERATEProcessorAll MF DMA blockxxC0CF
SERIOUSFailure with paired
volumes
Pair suspend due to RIO path blockxx0xD4
SERIOUSFailure with paired
volumes
Pair suspend due to failure detected in M-VOLxx1xD4
SERIOUSFailure with paired
volumes
Pair suspend due to failure detected in R-VOLxx2xD4
SERIOUSFailure with paired
volumes
Pair suspend due to DFW/DRV CAC off from
R-VOL
xx3xD4
SERIOUSFailure with paired
volumes
Pair suspend due to the suspend report from
R-VOL
xx4xD4
SERIOUSFailure with paired
volumes
Pair suspend due to the Simplex report from
R-VOL
xx5xD4
SERIOUSFailure with paired
volumes
R-VOL has been suspended because an
unrecoverable failure occurred in the remote copy
connection
xx6xD4
SERIOUSFailure with paired
volumes
Pair suspend due to failurexx7xD4
SERIOUSFailure with paired
volumes
Abnormal status occurring during ERASE
operation in migration copy
xx8xD4
SERIOUSFailure with paired
volumes
SERVICE level SIM reported from RCUxxCxD4
MODERATEFailure with paired
volumes
MODERATE level SIM reported from RCUxxDxD4
SERIOUSFailure with paired
volumes
ACUTE/SERIOUS level SIM reported from RCUxxExD4
SERIOUSFailure with paired
volumes
Suspicion of the pair status failurexxFxD4
SERIOUSFailure with paired
volumes
Volume used as P-VOL has been suspended
(Unable to restore path)
xx0xDC
SERIOUSFailure with paired
volumes
Volume used as P-VOL has been suspended
(MCU failure detected)
xx1xDC
SERIOUSFailure with paired
volumes
Volume used as P-VOL has been suspended (RCU
failure detected)
xx2xDC
SERIOUSFailure with paired
volumes
Volume used as P-VOL has been suspended
(S-VOL suspension detected)
xx4xDC
SERIOUSFailure with paired
volumes
Volume used as P-VOL has been suspended
(S-VOL pair deletion detected)
xx5xDC
26 SNMP failure trap reference