90 HP StorageWorks MSA500 G2 Storage System User Guide
Description: The controller firmware detected a critical error. To prevent any
possible data loss, the firmware has entered a lock-up state. The code contains
engineering-specific information about the lock-up condition. Contact HP
support.
Action:
1. Remove the failing controller.
2. Wait 10 seconds.
3. Reinstall the controller, and be sure that it seats fully in the chassis.
If this action does not solve the problem, contact HP support.
04 Enable Volumes ? '<'=NO, '>'=YES
Type: User Input
Description: An issue exists with all configured volumes that may result in data
loss.
Action: Refer to display messages for more information.
05 System Name: <name>
Type: Informational
Description: Displays the user assigned name for the MSA500 G2 storage
system. This name can be assigned using ACU.
Action: None