Using Command Console 3-49
Compaq Confidential – Need to Know Required
Writer: Bob Young Project: Command Console V2.2 for the RAID Array 3000 (Pedestal and Rack Mount Models) User’s Guide Comments:
Part Number: AA-RBF2C-TE File Name: d-ch3 Using Command Console.doc Last Saved On: 12/5/00 10:20 AM
Assigning a Pager Code to a Subsystem Controller
1. Click a subsystem controller in the Navigation window.
2. From the File menu, click Properties.
3. Click the Event Notification tab.
4. Enter a three-digit number in the Pager Identification Number text box.
Viewing and Changing a Pager Critical Event
Code
1. From the Options menu, click Event Notification Pager Codes.
2. Click the code you want to edit, then select Edit.
3. Type the new four-digit pager code in the text box. The default codes
are shown in Table 3-1.
Table 3-1
Pager Critical Event Codes
Critical Event Code Description
Disk fault 1000 Physical device failure
Power supply fault 1001
Fan fault 1002
Battery fault 1003
Temperature fault 1004
Controller fault 1005 Controller has detected internal fault.
Communication fault 1006
Agent cannot communicate with
subsystem.
Other Controller fault 1007
One controller is reporting a fault on other
controller.
External fault 1008
LUN fault 1009 Virtual disk failure