Controller Display Messages
48 MSA1000 Controller User Guide
106 VOLUME #<n>
STATE WAITING TO
REBUILD
Informational The configured volume is
waiting to start rebuilding
data on a SCSI drive that
replaces a previously failed
drive. The rebuild may not
have started yet because
the array controller is
already performing a
rebuild on another
configured volume.
107 VOLUME #<n>
STATE WAITING TO
EXPAND
Informational The configured volume is
waiting to start a volume
expansion operation. The
expansion may have not
started yet because another
configured volume is
undergoing expansion or a
rebuild is occurring on the
configured volume.
108 VOLUME #<n>
STATE MISSING
DRIVES
Error The configured volume is
missing too many of the
SCSI drives that it is
composed of making it
unusable. The volume will
be disabled.
Power off the MSA1000
and then all attached
storage enclosures. Unplug
and reinsert all SCSI drives
insuring they are fully
seated in their bays. Check
the cables connecting the
MSA1000 to any attached
storage enclosures. Power
on the attached storage
enclosures and then the
MSA1000.
109 VOLUME #<n>
STATE WRONG
DRIVE REPLACED
Error The configured volume
appears to have had
known, good SCSI drives
replaced instead of known,
failed drives.
The MSA1000 should be
powered off and the good
drives should be restored
while the failed drives
should be replaced.
Table 3: LCD Message Descriptions
Message Type Description Action