7. Utility Reference
344
Optional: If a key and its setting are not specified, one of the following values will
be used:
For a new installation
The default value will be used.
For an upgrade installation or re-installation:
The previous setting will be inherited.
Note:
Setting of audit logs is not supported.
#1
Enter one key and one setting per line.
#2
If the value is not of an allowable type, an error will occur.
For details about the functions set by these keys, see 6.6 set (Sets Up the
Operating Environment).
#3
You can specify this key only in the following cases:
For a new installation:
When
on is specified for the auto_failback key in the installation
information settings file
For an upgrade installation or re-installation:
When
on is specified for the auto_failback key in the installation
information settings file, or when automatic failback is enabled in the
installation pre-settings
#4
If you want to enable intermittent error monitoring, specify this key after
specifying the
auto_failback and auto_failback_interval keys.
The following shows an example of an edited installation information settings file.
[INSTALLATION_SETTINGS]
installfile_location=/dev/cd0
logdir=/var/tmp
licensekeyfile=/var/tmp/hdlm_license
licensekey=/var/DLM/dlm.lic_key
driver_config=y
restart=n