Hp D2D100 Backup System Bedienungsanleitung Seite 112

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 126
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 111
Email alerts tro
ubleshooting
If you are not re
ceiving email alerts, use the Test button on the Email Alerts page to send a test email. If this
fails, make sur
e the email server is congured correctly. See Email Alerts (Conguration) on page 74
for more inform
ation.
Disk troubleshooting
HP D2D Backup System runs out of space
Disk fails on the HP D2D Backup System
If the HP D2D B
ackup System runs out of space
A warning mes
sage is generated when the HP D2D Backup System reaches 90% capacity. You cannot
add physica
l disk space, but you may be able to create some space. Options for creating space include:
Review your backup jobs to see if you can reduce the size of backup or retention tim e.
Use the b a ckup application job settings to overwrite or erase data.
Export a ca
rtridge to an attached tape drive.
If a disk fails
The Disk Status LED will ash orange, if a disk fails. The Web Management Interface will help you
identify the disk that has failed. The HP D2D Backup System operates c orrectly with three disks, but
protection is limited. It is i mportant to replace the failed disk as soon as possible.
For more information, see Hard disk replacement on page 113.