10.6
Administrative Tables
3PAR System Reporter User’s Guide System Reporter 2.8
metric VARCHAR(32) NOT
NULL
The metric that is calculated. The
supported values depend on the
data_table value.
direction VARCHAR(32) NOT
NULL
How the metric is compared against the
limit_val. Currently this should be either >
(greater than) or < (less than).
limit_val DOUBLE PRECISION
NOT NULL
The calculated metric is compared based
on direction against limit_val.
limit_count INTEGER NOT NULL In each sample interval if the number of
objects for which the metric values exceed
limit_val when compared using direction
is greater than limit_count then an email
alert is generated.
condition_code VARCHAR(32) Defines an additional condition that must
be met for certain alerts to be generated.
See Condition on page 7.17.
condition_val DOUBLE PRECISION
NOT NULL
Defines a value used in conjunction with
condition_code. See Condition Value on
page 7.17.
recipient VARCHAR(64) The email address to which alerts for this
rule should be sent.
Table 10-4. alertconfig_2 Table
Column Type Comment
Seitenansicht 297