Hp 3000 Enterprise Virtual Array Bedienungsanleitung Seite 180

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 244
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 179
EMU Generated Condition Reports
180 Enterprise Virtual Array 3000 User Guide
0.7.01.15 UNRECOVERABLE ConditionEMU Hardware Failure
The EMU is inoperative and must be replaced NOW! This condition report
remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then
contact your HP authorized service representative.
0.7.01.16 INFORMATION ConditionEMU Internal ESI Data Corrupted
The EMU ESI data is corrupted. This condition does not affect any other element
and no action is required.
0.7.01.17 UNRECOVERABLE ConditionPower Shutdown Failure
The power supply did not respond to a controller, EMU, or power supply shut
down command. Shutting down the supply is required to prevent overheating.
Complete the following procedure to correct the problem:
1. Record all six characters of the condition report.
2. Move the power cord bail lock 1, Figure 67, to the left.
3. Disconnect the AC power cord 2 from the supply.
Figure 67: Disconnecting AC power
CXO7490A
2
3
1
4
Seitenansicht 179
1 2 ... 175 176 177 178 179 180 181 182 183 184 185 ... 243 244

Kommentare zu diesen Handbüchern

Keine Kommentare