HP 2000i G2 Modular Smart Array
User Guide
Part number: 481598-005
First edition: January 2013
Seitenansicht 0
1 2 3 4 5 6 ... 71 72

Inhaltsverzeichnis

Seite 1 - User Guide

HP 2000i G2 Modular Smart ArrayUser GuidePart number: 481598-005First edition: January 2013

Seite 3 - Contents

HP 2000i G2 Modular Smart Array User Guide 11About this guideThis guide provides information about the HP StorageWorks 2312i G2 Modular Smart Array an

Seite 4

12Document conventions and symbolsWARNING! Indicates that failure to follow directions could result in bodily harm or death.CAUTION: Indicates that fa

Seite 5

HP 2000i G2 Modular Smart Array User Guide 13Rack stabilityWARNING! To reduce the risk of personal injury or damage to equipment:• Extend leveling jac

Seite 6

14• http://www.hp.com/go/msa• http://www.hp.com/service_locator • http://www.hp.com/go/storage • http://www.hp.com/support/ • http://www.docs.hp.com D

Seite 7

HP 2000i G2 Modular Smart Array User Guide 151OverviewThe 2312i G2 Modular Smart Array and 2324i G2 Modular Smart Array are high-performance storage s

Seite 8

16 Overview

Seite 9

HP 2000i G2 Modular Smart Array User Guide 172ComponentsFront panel components2312i G22324i G21 Enclosure ID LED2 Disk drive Online/Activity LED3 Disk

Seite 10

18 ComponentsDisk drive bay numbers2312i G22324i G2Rear panel components 2312i G2 and 2324i G2MSA2000123456789101112MSA20001 2 3 4 5 6 7 8 9 101112131

Seite 11 - About this guide

HP 2000i G2 Modular Smart Array User Guide 19MSA2000 3.5" 12-drive enclosureMSA70 2.5” 25-drive enclosureThe 2324i G2 can also be attached to an

Seite 12 - Monospace, italic font

Legal and notice information© Copyright 2009, 2013 Hewlett-Packard Development Company, L.P.The information combined herein is subject to change witho

Seite 13

20 ComponentsCAUTION: To preserve the existing data stored in the CompactFlash, you must transport the CompactfFlash from the failed controller to the

Seite 14 - Documentation feedback

HP 2000i G2 Modular Smart Array User Guide 213Installing the enclosuresInstallation checklistThe following table outlines the steps required to instal

Seite 15 - 1Overview

22 Installing the enclosuresConnecting controller and drive enclosuresConnecting controller and MSA2000 3.5" 12-drive enclosuresYou can connect u

Seite 16 - 16 Overview

HP 2000i G2 Modular Smart Array User Guide 23Table 3 SAS cable requirementsMini-SAS to SAS cables must be purchased separately.0.5m cables are recomme

Seite 17 - 2Components

24 Installing the enclosuresFigure 3 Cabling connections between a dual-controller enclosure and three MSA2000 3.5" 12-drive enclosuresFigure 4 C

Seite 18 - Rear panel components

HP 2000i G2 Modular Smart Array User Guide 25Figure 5 Cabling connections between a dual-controller enclosure and three MSA70 drive enclosures0B0ACont

Seite 19 - Transportable CompactFlash

26 Installing the enclosuresFigure 6 Cabling connections between a dual-controller enclosure and mixed drive enclosures.TIP: For comprehensive configu

Seite 20 - Super-capacitor pack

HP 2000i G2 Modular Smart Array User Guide 27Obtaining IP valuesNOTE: For help with configuring your MSA2000 G2 product, also see the MSA2000 Software

Seite 21 - 3Installing the enclosures

28 Installing the enclosures2. Use the provided micro-DB9 serial cable to connect controller A to a serial port on a host computer.Your package conten

Seite 22 - 22 Installing the enclosures

HP 2000i G2 Modular Smart Array User Guide 29# set network-parameters ip 192.168.0.11 netmask 255.255.255.0 gateway 193.168.0.10 controller b7. Type t

Seite 23

HP 2000i G2 Modular Smart Array User Guide 3About this guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 24

30 Installing the enclosures

Seite 25

HP 2000i G2 Modular Smart Array User Guide 314 Connecting hostsHost system requirementsData hosts connected to 2312i G2 and 2324i G2 arrays must meet

Seite 26 - Testing enclosure connections

32 Connecting hostsThe 2312i Modular Smart Array and 2324i Modular Smart Array use Unified LUN Presentation (ULP) — a controller firmware feature enab

Seite 27 - Obtaining IP values

HP 2000i G2 Modular Smart Array User Guide 335 Basic operationPowering on/powering offBefore powering on the enclosure for the first time:• Install al

Seite 28 - ACTIVITY

34 Basic operationFor software and firmware updates, go to http://www.hp.com/go/msa. Select MSA SAN Arrays, select your product, and go to Support.For

Seite 29 - IP-address

HP 2000i G2 Modular Smart Array User Guide 356 LED descriptionsFront panel LEDsLED Description Definition1 Enclosure ID Green — OnEnables you to corre

Seite 30 - 30 Installing the enclosures

36 LED descriptionsDisk drive LEDsLED Description1 Fault/UID (amber/blue)2Online/Activity (green)Table 6 Disk drive LED combinations Online/Activity (

Seite 31 - 4 Connecting hosts

HP 2000i G2 Modular Smart Array User Guide 37Rear panel LEDs2312i G2 and 2324i G2Blinking regularly (1 Hz) OffCAUTION: Do not remove the drive. Removi

Seite 32 - One server/one HBA/dual path

38 LED descriptionsNOTE: Once a Link Status LED is lit, it remains so, even if the controller is shutdown via SMU or CLI.When a controller is shutdown

Seite 33 - 5 Basic operation

HP 2000i G2 Modular Smart Array User Guide 39MSA2000 3.5" 12-drive enclosureMSA70 2.5” 25-drive enclosureThe 2324i G2 can also be attached to an

Seite 34 - 34 Basic operation

45 Basic operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Powering on/powering off

Seite 35 - 6 LED descriptions

40 LED descriptionsPower supply LEDsPower redundancy is achieved through two independent load-sharing power supplies. In the event of a power supply f

Seite 36 - Disk drive LEDs

HP 2000i G2 Modular Smart Array User Guide 417 Configuring a system for the first timeConfiguring your web browser for SMUBefore using SMU to perform

Seite 37 - Rear panel LEDs

42 Configuring a system for the first time• The System Status panel shows how many events of each severity have occurred in the system. To view event

Seite 38

HP 2000i G2 Modular Smart Array User Guide 43To obtain the date and time from an NTP server1. In the Configuration View panel, right-click the system

Seite 39

44 Configuring a system for the first timeUsing the Configuration WizardThe Configuration Wizard helps you initially configure the system or change sy

Seite 40 - Power supply LEDs

HP 2000i G2 Modular Smart Array User Guide 45Using the Provisioning WizardThe Provisioning Wizard helps you create a vdisk with volumes, and to map th

Seite 41 - Signing in to SMU

46 Configuring a system for the first time

Seite 42

HP 2000i G2 Modular Smart Array User Guide 478TroubleshootingFault isolation methodologyThe 2000sa G2 Modular Smart Array storage system provides many

Seite 43

48 TroubleshootingCorrecting enclosure IDs When installing a system with drive enclosures attached, the enclosure IDs might not agree with the physica

Seite 44

HP 2000i G2 Modular Smart Array User Guide 49Are both drive module LEDs off (Online/Activity and Fault/UID)?Is the drive module Fault/UID LED blinking

Seite 45 - Signing out of SMU

HP 2000i G2 Modular Smart Array User Guide 5A Environmental requirements and specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 46

50 TroubleshootingIs a connected port’s Expansion Port Status LED off?Is a connected port’s Network port link status LED off?Is the power supply’s AC

Seite 47 - 8Troubleshooting

HP 2000i G2 Modular Smart Array User Guide 51Is the drive enclosure Fault/Service Required LED amber?Answer Possible Reasons ActionsNo System functio

Seite 48 - Diagnostic steps

52 TroubleshootingController failure in a single-controller configurationCache memory is flushed to CompactFlash in the case of a controller failure o

Seite 49

HP 2000i G2 Modular Smart Array User Guide 53Isolating a host-side connection fault During normal operation, when a controller module host port is con

Seite 50 - 50 Troubleshooting

54 TroubleshootingIsolating a controller module expansion port connection fault During normal operation, when a controller module’s expansion port is

Seite 51

HP 2000i G2 Modular Smart Array User Guide 55Sensor locationsThe storage system monitors conditions at different points within each enclosure to alert

Seite 52 - Transporting Cache

56 TroubleshootingWhen a power supply sensor goes out of range, the Fault/ID LED illuminates amber and an event is logged to the event log.Power suppl

Seite 53

HP 2000i G2 Modular Smart Array User Guide 57A Environmental requirements and specificationsSafety requirementsInstall the system in accordance with t

Seite 54 - 54 Troubleshooting

58 Environmental requirements and specificationsWeight and placement guidelinesRefer to Physical requirements on page 59 for detailed size and weight

Seite 55 - Temperature sensors

HP 2000i G2 Modular Smart Array User Guide 59NOTE: Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods

Seite 57 - Safety requirements

60 Environmental requirements and specificationsElectrical requirementsSite wiring and power requirementsEach enclosure has two power and cooling modu

Seite 58 - Management host requirements

HP 2000i G2 Modular Smart Array User Guide 61B Electrostatic dischargePreventing electrostatic dischargeTo prevent damaging the system, be aware of th

Seite 59 - Environmental requirements

62 Electrostatic discharge

Seite 60 - Electrical requirements

HP 2000i G2 Modular Smart Array User Guide 63C Regulatory compliance and safetyRegulatory complianceFederal Communications Commission noticePart 15 of

Seite 61 - B Electrostatic discharge

64 Regulatory compliance and safety• 1-281-514-3333To identify this product, refer to the part, Regulatory Model Number, or product number found on th

Seite 62 - 62 Electrostatic discharge

HP 2000i G2 Modular Smart Array User Guide 65Laser product labelThe optional label in Figure 6-1 or equivalent may be located on the surface of the HP

Seite 63 - Regulatory compliance

66 Regulatory compliance and safetyBSMI noticeJapanese noticeKorean noticesSafetyBattery replacement noticeYour computer is equipped with a lithium ma

Seite 64

HP 2000i G2 Modular Smart Array User Guide 67WARNING! Your computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkali

Seite 65 - European Union notice

68 Regulatory compliance and safety• Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.• Place part

Seite 66 - Battery replacement notice

HP 2000i G2 Modular Smart Array User Guide 69IndexAaccessingthe CLI 27accessing the SMU 41accumulators 67audience 11Avis Canadien, regulatory complian

Seite 67 - Electrostatic discharge

HP 2000i G2 Modular Smart Array User Guide 7Figures1 Cabling connections between a single-controller enclosure and one MSA2000 3.5" 12-drive enc

Seite 68 - Grounding methods

70Ffaultsisolatinga host-side connection 53expansion port connection fault 54methodology 47FCC (Federal Communications Commission)Class A Equipment, c

Seite 69

HP 2000i G2 Modular Smart Array User Guide 71current rating 67replacement 67set 67voltage rating 67power cord requirements 60power supplyLEDs 37sensor

Seite 70

72HP storage 14HP Subscriber’s choice 13web-browser configuration 41work mat, static-dissipating 68wrist strapsspecifications 68using 68

Seite 72

HP 2000i G2 Modular Smart Array User Guide 9Tables1 Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Kommentare zu diesen Handbüchern

Keine Kommentare