5. Make the settings to all the LDEVs in the LDKC:CU:LDEV column (repeat step 2 through step
4).
6. Click OK.
The specified numbers are assigned to the LDEVs. However, the Add Volume dialog box shows
only the LDEV number assigned for the first LDEV of each external volume.
Figure 30 Example of LDEV Mapping (Manual) Dialog Box
You can also assign contiguous LDEV numbers to LDEVs using this dialog box. To assign contiguous
LDEV numbers to LDEVs, select multiple LDEVs at step 2, and specify the starting LDEV number at
step 3 and 4. You can set Interval if necessary.
Setting the Cross-subsystem Paths
You need to configure the cross-subsystem path from the internal volume to the external volume
before using the external volume mapped as an internal volume. For details on the cross-subsystem
path, see “Cross-subsystem Paths” (page 18).
You can configure the cross-subsystem path when you map the external volume as the internal
volume. You can also add or change the cross-subsystem paths after the mapping operation is
78 Performing XP External Storage Operations