ibrix_powersrc
Adds or deletes power sources and modifies power source attributes in the configuration database.
Description
Programmable power sources are required for automated failover and forced manual failover.
The installed power sources must be identified and added to the configuration database before
they can be used. X9000 Software works with APC power sources and with integrated power
sources that are managed by iLO, IPMI, or OpenIPMI.
To implement automated failover or to centrally manage power sources, the management console
must have LAN access to all identified power sources.
All types of power sources must be identified to the configuration database with ibrix_powersrc
-a before they can be used. After you identify an APC power source, execute ibrix_hostpower
to identify the slots where file serving nodes are connected. File serving nodes with integrated
power sources are connected to slot 1 by default, making it unnecessary to declare a slot association
for them.
If you move a file serving node to a different APC slot, unplug a file serving node from a slot, or
change a power source’s IP address or password, use
nl
ibrix_powersrc -m to update the configuration database with the changes.
You can use ibrix_powersrc -d to dissociate a file serving node from a power source by
either dissociating it from a slot or dissociating it from the power source itself.
Synopsis
Add an APC power source:
ibrix_powersrc -a -t {apc|apc_msp} -h POWERSRCNAME -n NUMSLOTS -I IPADDR
The power source is identified by its name, number of slots, and IP address.
Activate an IPMI or iLO power source:
ibrix_powersrc -a -t {openipmi|openipmi2|ilo} -h HOSTNAME -I IPADDR -u
USERNAME -p PASSWORD [-s]
The command activates the power source on the file serving node identified by name and IP
address. The -u and -p options are required. To have the management console skip BMC, include
the -s option.
Activate a VM-based power source:
ibrix_powersrc -a -t {esx} -h HOSTNAME -I IPADDR [-u USERNAME -p
PASSWORD] —C CONFPATH
The command activates the power source on the file serving node identified by name and IP
address. To secure access to the power source, include the -u USERNAME and -p PASSWORD
arguments.
Modify the IP address for APC power sources:
ibrix_powersrc -m -I IPADDR [-s] -h POWERSRCLIST
To have the management console skip BMC, include the -s option.
104 X9000 File Serving Software commands