Invalid Configuration detected by remote side
Meaning: A Point-to-Point configuration option that was not using auto-configure
is incompatible with the remote device.
Action: Use the auto-configure option to configure the Point-to-Point WAN
circuit on either the local or the remote device.
Lost carrier, disabling cct
Meaning: The router has detected the loss of the carrier signal on the
WAN circuit. The circuit is no longer in service.
Action: Check cable connections, check any modems, CSU/DSUs, and the line
itself.
No cct record for FDDI CCT %cct%
Meaning: No line has been configured for this FDDI circuit.
Action: Configure a line for this FDDI circuit.
QOS =
addr
, addr =
addr
, Compression =
compression
Meaning: Dynamic Link Establishments has negotiated the parameters for this end
of the WAN link as shown.
Event Log Messages
dls: Data Link Services Event Messages
17-72