System Unit
Dimensions
(H x W x D)
(with bezel)
3.46 x 17.64 x 28.1 in (8.79 x 44.80 x 71.37 cm)
Weight
(approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
53.7 lb (24.35 kg)
Input Requirements
(per power supply)
Rated Line Voltage
90 to 132 VAC
180 to 264 VAC
Rated Input Current
5. 8 Amps (at 100 VAC) to 2.9 Amps (at 200
VAC)
Rated Input Frequency
47 to 63 Hz
BTU Rating
Rated Input Power
570W (at 100 VAC)
565W (at 200 VAC)
Maximum
-500W 1940 BTU / hr (at 100 VAC), 1920
BTU/hr (at 200 VAC)
460W - 1773 BTU / hr (at 120 VAC), 1715 (at
240 VAC)
750W - 2892 BTU / hr (at 120 VAC), 2797 (at
240 VAC)
Power Specifications
To review typical system power ratings use the HP Power Advisor which
is available via the online tool located at URL:
www.hp.com/go/proliant-
energy-efficient
Power Supply Output
(per power supply)
Rated Steady-State
Power
500 Watts (at 100 VAC),
500 Watts (at 200 VAC)
Maximum Peak Power
(See Power
Specifications Tables)
500Watts (at 100 VAC),
500 Watts (at 200 VAC)
System Inlet
Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change
is 10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 30°C
(86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating
10 to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature, non-
condensing.
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Altitude
Operating
3050 m (10,000 ft). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is
457 m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and
QuickSpecs
HP ProLiant SL160z Generation 6 (G6)
Technical Specifications
DA - 13385 Worldwide QuickSpecs — Version 1 — 6.15.2009
Page 31
Seitenansicht 30
1 2 ... 26 27 28 29 30 31 32 33

Kommentare zu diesen Handbüchern

Keine Kommentare

Western Reserve Controls 1782-JDC manuály

Uživatelské manuály a uživatelské příručky pro Brány / ovladače Western Reserve Controls 1782-JDC.
Poskytujeme 3 manuály pdf Western Reserve Controls 1782-JDC ke stažení zdarma podle typů dokumentů: Uživatelský manuál






Další produkty a příručky pro Brány / ovladače Western Reserve Controls

Modely Typ Dokumentu
WRC-CANR-DF Uživatelský manuál   Western Reserve Controls WRC-CANR-DF User`s manual, 24 stránky