HP ProLiant BL620c Generation 7 (G7) Server Blade
HP ProLiant BL620c Generation 7 (G7) Server BladeHP ProLiant BL620c Generation 7 (G7) Server Blade
HP ProLiant BL620c Generation 7 (G7) Server Blade
1.
Two hot-plug small form factor (SFF) SAS/SATA/SSD bays
7.
Four NC553i 10Gb FlexFabric adapter ports
2.
Power on/standby button
8.
iLO 3 Management adapter port
3.
UID, health, and network adapter LEDs
9.
HP P410i Smart Array flash cache connector
4.
32 RDIMM slots supporting up to 1.0TB of DDR3-1333
memory (operating up to 1066 MHz)
10.
One or two Intel® Xeon® 6500 or 7500 Series processors
up to eight-cores each (below the hard drives)
5.
One USB 2.0 port, one MicroSD high capacity (SDHC) port,
and one TPM 1.2 connector
11.
Server release lever
6.
Three PCIe Gen2 I/O expansion mezzanine slots
What's New
What's NewWhat's New
What's New
Support for the new HP Smart Array P712m Controller
Support for the HP BLc NC360m NIC Adapter Option Kit
At A Glance
At A GlanceAt A Glance
At A Glance
This document covers the HP ProLiant BL620c G7 server blade only. For more information on the HP BladeSystem c-Class Enclosure
and HP BladeSystem c-Class Interconnects, please see the following:
HP BladeSystem c3000 Enclosure QuickSpecs:
QuickSpecs
HP ProLiant BL620c Generation 7 (G7) Server Blade
HP ProLiant BL620c Generation 7 (G7) Server BladeHP ProLiant BL620c Generation 7 (G7) Server Blade
HP ProLiant BL620c Generation 7 (G7) Server Blade
Overview
DA - 13747 Worldwide — Version 22 — March 6, 2012
Page 1
Seitenansicht 0
1 2 3 4 5 6 ... 42 43

Inhaltsverzeichnis

Seite 1 - QuickSpecs

HP ProLiant BL620c Generation 7 (G7) Server BladeHP ProLiant BL620c Generation 7 (G7) Server BladeHP ProLiant BL620c Generation 7 (G7) Server BladeHP

Seite 2

G7 or earlier BTO servers until the last supported server is no longershipping.The Media Kit will not be updated past version 8.70.ProLiant G7 or earl

Seite 3

High PerformanceHigh PerformanceHigh PerformanceHigh PerformanceClustersClustersClustersClustersHP Cluster PlatformsHP Cluster Platforms are specifica

Seite 4

on a read transaction.DIMM Address/Control Bus Parity Protection provides a means to detect and protect commandand address errors.Memory Failover uses

Seite 5

system.On-Die Error Protection protects registers from particle hits.StorageStorageStorageStorageTwo hot-plug SAS/SATA/SSD drive bays.Integrated HP Sm

Seite 6

Industry StandardIndustry StandardIndustry StandardIndustry StandardComplianceComplianceComplianceComplianceACPI 2.0 CompliantPCI 2.2 CompliantMicroso

Seite 7

HP EnterpriseHP EnterpriseHP EnterpriseHP EnterpriseConfiguratorConfiguratorConfiguratorConfiguratorThe HP eConfigure Enterprise Configurator now prov

Seite 8

Service and SupportService and SupportService and SupportService and SupportHP Technology Services for Industry Standard Servers and BladeSystemHP Tec

Seite 9

Standard Care PackageStandard Care PackageStandard Care PackageStandard Care PackagePackage that maintains high level of server availabilityPackage th

Seite 10

Provides for the deployment and basic configuration of HP Insight Control on HP ProLiant ML and DLseries servers or HP BladeSystem servershttp://h2019

Seite 11

Intel Xeon E7-2800/8867L ModelsIntel Xeon E7-2800/8867L ModelsIntel Xeon E7-2800/8867L ModelsIntel Xeon E7-2800/8867L ModelsNOTE:NOTE:NOTE:NOTE: For t

Seite 12

http://h18000.www1.hp.com/products/quickspecs/12790_div/12790_div.html(Worldwide)HP BladeSystem c7000 Enclosure QuickSpecs:http://h18000.www1.hp.com/p

Seite 13

Intel Xeon 6500 ModelsIntel Xeon 6500 ModelsIntel Xeon 6500 ModelsIntel Xeon 6500 ModelsHP ProLiant BL620c G7HP ProLiant BL620c G7HP ProLiant BL620c G

Seite 14

NOTE:NOTE:NOTE:NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areord

Seite 15

HP BL620c G7 Intel® Xeon® E7-8867L (2.13GHz/10-core/30MB/105W) FIOProcessor Kit643761-L21Eight-Core ProcessorsEight-Core ProcessorsEight-Core Processo

Seite 16

HP 32GB (1x32GB) Quad Rank x4 PC3L-8500 (DDR3-1066) Registered CAS-7 LPMemory KitNOTE:NOTE:NOTE:NOTE: This memory kit is only available on the Intel X

Seite 17

NOTE:NOTE:NOTE:NOTE: For additional "Core Options" and "Additional Options" please see the options sections below.HP Ethernet Mezz

Seite 18

HP ProcessorsHP ProcessorsHP ProcessorsHP ProcessorsNOTE:NOTE:NOTE:NOTE: The BL620c G7 supports one or two processors.NOTE:NOTE:NOTE:NOTE: The minimum

Seite 19

HP MemoryHP MemoryHP MemoryHP MemoryNOTE:NOTE:NOTE:NOTE: All DDR3 memory option kits consist of one RDIMM per kit.NOTE:NOTE:NOTE:NOTE: PC3L is a low-v

Seite 20

HP 300GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty HardDrive507127-B21HP 146GB 6G SAS 15K rpm SFF (2.5-inch) Dual Port Enterpris

Seite 21

HP Insight SoftwareHP Insight SoftwareHP Insight SoftwareHP Insight SoftwareInsight ControlInsight ControlInsight ControlInsight Control HP Insight Co

Seite 22

http://h18000.www1.hp.com/products/quickspecs/13019_div/13019_div.html(Worldwide)HP Integrated Lights-Out (iLO) Advanced for ProLiant BladeSystem Remo

Seite 23

Lower idle power that allows idling cores to be reduced to near-zero power independent of other cores, reducingserver idle power consumptionMeshed net

Seite 24

High PerformanceHigh PerformanceHigh PerformanceHigh PerformanceClustersClustersClustersClustersHP Cluster Management UtilityHP Cluster Management Uti

Seite 25

HP 512MB Flash Backed Write CacheNOTE:NOTE:NOTE:NOTE: This is an option for the HP Smart Array P410i Controller (P410i is standardintegrated controlle

Seite 26

HP Ultrium Tape BladesHP Ultrium Tape BladesHP Ultrium Tape BladesHP Ultrium Tape BladesHP LTO-4 SB1760c Tape BladeAQ697AHP LTO-5 SB3000c Tape BladeBS

Seite 27

HP Security - TPMHP Security - TPMHP Security - TPMHP Security - TPMHP Trusted Platform Module Option488069-B21NOTE: NOTE: NOTE: NOTE: The BL620c G7 s

Seite 28

1.2.3.4.5.6.7.8.9.10.11.Memory Subsystem ArchitectureMemory Subsystem ArchitectureMemory Subsystem ArchitectureMemory Subsystem ArchitectureFor maximu

Seite 29

Up to 832GB of memory is available with the installation of optional DDR3 RDIMM memory expansion kits (BL620c G7 Intel XeonE7-2800/8867L models).Up to

Seite 30

MemoryMemoryMemoryMemoryProcessor 1 RDIMM SlotsProcessor 1 RDIMM SlotsProcessor 1 RDIMM SlotsProcessor 1 RDIMM Slots(Processor 2 has the same RDIMM sl

Seite 31

NOTE:NOTE:NOTE:NOTE: All DDR3 memory option kits consist of one RDIMM per kit.NOTE:NOTE:NOTE:NOTE: PC3L is a low-voltage memory and is only available

Seite 32

1-22 x SFF SAS/SATA/SDD hot-plug hard drivesHard DrivesHard DrivesHard DrivesHard DrivesNOTE:NOTE:NOTE:NOTE: The components of a storage subsystem (e.

Seite 33

6G SAS Hot Plug Enterprise Performance Solid State Drives6G SAS Hot Plug Enterprise Performance Solid State Drives6G SAS Hot Plug Enterprise Performan

Seite 34

NOTE:NOTE:NOTE:NOTE: SAS, SATA, and/or SSD drives cannot be mixed within the server.Network ControllerNetwork ControllerNetwork ControllerNetwork Cont

Seite 35

System UnitSystem UnitSystem UnitSystem UnitDimensionsDimensionsDimensionsDimensions(H x W x D)Full height, single-wide server blade:14.46 x 2.19 x 20

Seite 36

Enclosures QuickSpecs located at:HP BladeSystem c3000 Enclosure QuickSpecs:http://h18000.www1.hp.com/products/quickspecs/12790_div/12790_div.htmlHP Bl

Seite 37

10Gb Ethernet ort 1Gb Ethernet autosensingMicrosoft TCP chimney compliantSupports 8 Physical Functions (PF)Supports 128 Virtual Functions (VF):Up to 3

Seite 38

Client Browser SupportClient Browser SupportClient Browser SupportClient Browser SupportMicrosoft Internet Explorer 8Microsoft Internet Explorer 7Micr

Seite 39

Operating System SupportOperating System SupportOperating System SupportOperating System Support:Microsoft Windows, RHEL, SLES, Oracle Solaris, VMware

Seite 40

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information -

Seite 41

UpgradeabilityUpgradeabilityUpgradeabilityUpgradeabilityUpgradeable to two processorsNOTE:NOTE:NOTE:NOTE: All processors within the server must be ide

Seite 42

Network ControllersNetwork ControllersNetwork ControllersNetwork ControllersFour (4) integrated HP NC553i 10Gb FlexFabric adapter ports supporting 10G

Seite 43

Fibre ChannelFibre ChannelFibre ChannelFibre ChannelUp to three (3) optional 4Gb and/or 8Gb Fibre Channel HBA mezzanine adapters (Brocade, Emulexand Q

Kommentare zu diesen Handbüchern

Keine Kommentare