HP Vectra VA6 Betriebsanweisung Seite 59

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 96
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 58
English 47
Appendix A The Error Codes
0001h – 00CCh: System Error Codes
0062h The Real Time Clock is running at a faster
rate.
Real Time Clock (RTC) error.
Install new system board.
0063h The date and time read from Real Time
Clock CMOS RAM are different from that
of written.
CMOS RAM error.
Install new system board.
0070h The battery backup unit that powers
CMOS RAM has no power.
Install new system board battery.
0071h Bad CMOS RAM checksum detected. CMOS RAM error.
Install new system board battery.
If error persists, install new system board.
0072h Configuration mismatch in CMOS RAM. CMOS RAM error.
Install new system board battery.
If error persists, install new system board.
0073h CMOS RAM memory size. CMOS RAM error.
Install new system board battery.
If error persists, install new system board.
0074h CMOS RAM time is invalid. CMOS RAM error.
Install new system board battery.
If error persists, install new system board.
0075h Time-base frequency divider set at
incorrect value.
CMOS RAM error.
Re-start system and check BIOS setup parameters.
Install new system board battery.
If error persists install new system board.
0076h Divider output frequency set to an
incorrect value.
CMOS RAM error.
Re-start system and check BIOS setup parameters.
Install new system board battery.
If error persists install new system board.
Code Explanation Details/Parts to Check
guard.bk : g-e-ref1.fb4 Page 47 Wednesday, June 30, 1999 3:06 PM