Specifications 33
Configuration setting (VAC) Available nominal output voltage (VAC)
230 230
240 240
Output tolerance specifications
Source of power Regulation
Utility power (nominal
range)
-10% to +6% of nominal output voltage rating
(within the guidelines of the Computer Business
Equipment Manufacturers Association)
Battery power ±5% of nominal output voltage rating
Output feature specifications
Feature Specification
Online efficiency 94% nominal input voltage
Voltage wave shape Sine wave; 5% THD with typical PFC load; 15-20% THD on battery
Surge suppression High-energy 6500 A peak
Noise filtering MOVs and line filter for normal and common mode use
Battery specifications
Feature Specification
Type 12 V, 9 AH, sealed, maintenance-free, rechargeable, lead-acid battery.
Charging
Complete charge takes no more than 24 hours. After approximately 4 hours, the batteries
reach 90% charge at default nominal utility voltage and no load.
Battery runtime
Load, percent Load, watts Estimated battery runtime at 100% battery charge
20 100 45 minutes
50 250 15 minutes
80 400 6 minutes
100 500 4 minutes
Environmental specifications
Feature Specification
Operating temperature 0°C to 40°C (32°F to 104°F)
Nonoperating temperature -15°C to 50°C (5°F to 122°F)
Relative humidity 0% to 95%; noncondensing