Parker Hannifin Corporation
Instrumentation Valve Division
Jacksonville, Alabama
2
HB Series Ball Valves
Features
Suparcase
®
ball/trunnion for longer cycle life
Two-way and three-way designs
Compact FNPT version for tight work areas
Blow-out resistant two-piece ball/stem
Full operating pressure at any port
Low operating torque
Manual, electric or pneumatic actuation
Panel mountable to 3/8" (9.6 mm) thickness
No packing to adjust
Color coded fracture resistant handles
Handle indicates direction of flow
Positive handle stops
Wide variety of US Customary and SI ports
Top of stem marked to indicate flow direction
100% factory tested
Compact package
Heat code traceability
Specifications
Pressure rating: 10,000 psig (689 bar) CWP
with PEEK (PKR) Seats;
6,000 psig (414 bar) CWP
with PCTFE (K) Seats
Temperature rating: -65 ˚F to 400 ˚F (-54 ˚C to 204 ˚C)
Body material: Stainless Steel
Body configurations: Two-way and Three-way
Port connections: Tube compression (CPI
TM
/ A-LOK
®
);
Short and Long Female NPT
Port size: 1/8" - 1/2" (6mm to 12mm)
Flow Data
Two-way HB4L:
C
v
= 1.02;
x
T
= 0.42; Orifice = 0.188" (4.8 mm)
Three-way HB4X:
C
v
= 0.62;
x
T
= 0.71; Orifice = 0.188" (4.8 mm)
Tested in accordance with ISA S75.02. Gas flow will be choked
when
P
1
-
P
2
/
P
1
=
x
T
.
Testing
Standard production testing - valves are 100% factory
tested with nitrogen at 1,000 psig (69 bar) for leakage at
the seats and body seals. Both areas are required to have
less than 0.1 SCCM leakage. Optional testing is available
upon request. Consult your authorized Parker Instrumentation
Distributor or the factory for further information.
Introduction
Parker High Pressure HB4 Series Ball Valves, featuring Suparcase
®
ball and trunnions, provide reliable shut-off or switching
functions. The Suparcase
®
trunnion style ball enhances the resistance of the trunnions against seizure and the resistance of
the spherical ball to particle abrasion. The compact and rugged design employs spring-loaded seats for high cycle life and low
operating torques at pressures up to 10,000 psig (689 bar).
Two-way HB4L design