QuickSpecs
HP Business Desktop d325 Series
DA-11642 North America — Version 7 — August 22, 2003 12
Standard Features – Base Unit Details
ROM Features Description
Microtower Slim Tower
Master Boot Record Security
Allows for detection of changes to MBR and optional restoration,
useful in protecting from viruses
Yes Yes
Remote ROM Flash
Provides secure, fail-safe ROM image management from a central
network console
Yes Yes
Power Management ----- Yes Yes
ACPI Ready ----- Yes Yes
SMBIOS (previously known a DMI) System Management BIOS, previously known as DMI BIOS, for
system management information
Yes Yes
Keyboard-less Operation
The system can be operated without a keyboard
Yes Yes
Remote ROM Flash Provides secure, fail-safe ROM image management from a
central network console
Yes Yes
Remote Wakeup /
Remote Shutdown
• Allow a system administrator to power on, restart, and power
off a client computer from a remote location.
• This enables cost-effective power consumption when the
administrator needs to distribute software, perform security
management, or update the ROM.
Yes Yes
ROM Based Setup (F10) and Start-
up Diagnostics
-----
Yes Yes
System Environmental Specs
Acoustics: Advanced Power
Management – On
Seated operator position Idle (Hard drive
spinning but not
seeking) = 23 dBA
Idle (Hard drive spinning
but not seeking) = 27
dBA
Shock
Operating
(*Using 11-ms half-sine shock pulse)
-----
5 G’s* (with no
damage being
incurred)
5 G’s* (with no damage
being incurred)
Non-Operating
(*Using 11-ms half-sine shock pulse)
-----
10 G’s*, positive and
negative directions
front to back axis: 20
G’s* in all other axes
10 G’s*, positive and
negative directions front
to back axis: 20 G’s* in
all other axes
Vibration
Operating
----- Random vibration at
0.000215 G²/Hz, 10Hz
to 300Hz, (0.25G’s
nominal)
Random vibration at
0.000215 G²/Hz, 10Hz
to 300Hz, (0.25G’s
nominal)
Non-Operating
----- Random vibration at
0.0005 G²/Hz, 10Hz to
500Hz, (0.5G’s
nominal)
Random vibration at
0.0005 G²/Hz, 10Hz to
500Hz, (0.5G’s nominal)
Relative Humidity
Operating
(maximum wet bulb temp., non-
condensing)
-----
10% to 90% relative
humidity (Rh), 28°C
10% to 90% relative
humidity (Rh), 28°C
Non-operating
(maximum wet bulb temp., non-
condensing)
-----
5% to 95% relative
humidity (Rh), 38.7°C
5% to 95% relative
humidity (Rh), 38.7°C
Altitude Max (un-pressurized)
Operating
(Maximum allowable altitude change
rate is 1500 ft/min.)
-----
0 to 3,048 meters/
10,000 feet – This
value may be limited
by the type and
number of options
installed.
0 to 3,048 meters/
10,000 feet – This value
may be limited by the
type and number of
options installed.
Non-operating
(Maximum allowable altitude change
rate is 1500 ft/min)
-----
0 to / 9,144 m/30,000 ft 0 to / 9,144 m/30,000 ft
Kommentare zu diesen Handbüchern