C-16 Confi guring the EEPROM
The three columns in the RS-232 menu are similar to the Configurable Interfaces
menu:
• Key indicates the feature you want to select. To exit the interface menu, type
<X> <RETURN>.
• Feature lists each configurable function for the selected interface,
• Value shows the current value (or mode) for each function.
Note that all Interface menus are not the same. Each has its own features available for
configurations.
When you select an interface’s function, the prompt line changes. An example is the
RS-232’s Select Code. After you have selected the RS-232 interface to configure, and
you want to change its select code, type the following command:
1 < Return >
The following output appears:
1 Select Code 9
used select codes are :
12 14 15 21
Type 0.. 31 except used RETURN ?
Note the select code function line appears like it does in the main part of the RS-232
menu. The current select code appears at the right. Select codes already used in your
system unit are not available and are listed in the third line.
At the bottom, you’ll see the prompt line. This example means you would enter a select
code between 0 and 31, except for select codes 12, 14, 15 and 21. If you want to use se-
lect code 23, you would enter the command:
23 < Return >
Other features would be selected and changed the same way. After you have made all
the changes to the RS-232 Interface that your system unit needs, exit the RS-232 menu
by entering the command
X < Return >