1. Using the terminal emulator window used previously, display the current version of firmware
installed on the array using the show system version command. Ensure that the new
firmware being transferred is the same or newer version.
WARNING! Do not attempt to backdate or downgrade to an older version of firmware on
the VMA Array.
The following example shows where to find the firmware version as displayed with the show
system version command.
2. If not already there, change to the directory folder containing the scp utility and the VMA
Array firmware file (.upg file). In this example as created in step 2.b, the C:\VMAupgrade
folder.
3. Verify the pscp.exe utility and the firmware files are present with the dir command.
4. Use the pscp utility to copy the VMA Array firmware file from the Laptop to the VMA array
using the following command:
<pscp <firmware upgrade file name> admin@<array ip-address >:/
This runs the PSCP command on the Laptop and copies the <firmware upgrade file name>
(example: v3000-a5-1-3-x8-slc.upg) file to the root directory (/.) of the VMA32xx Array
<array ip-address> using the admin account for authorization.
Example: C:\>pscp v3000-a5-1-3-x8-slc.upg admin@192.168.1.2:/
Transferring the new VMA firmware file to the VMA Array 19