34 Power Supply and Fan Modules
WARNING! Do not attempt to install a DC power supply into an NGFW Appliance. The NGFW
Appliance does not contain the grounding capability for safe installation of a DC power supply. Bodily
harm and damage to the system could result.
When the AC power supply has been securely placed in the appliance, use the following procedure to
connect power to the AC power supply:
1. Locate the male power input on the back of the chassis.
2. Plug one end of a standard female power plug into the power input.
3. Plug the other end into an AC outlet, power strip, or UPS. The power should meet the following
requirements:
Voltage: 100 – 240 VAC
•Current: 12 6 Amps
Frequency: 47 – 63 Hz
4. The NGFW Appliance returns to its previous power-on state in the event of a power interruption. If
power was on when the interruption occurred, the appliance automatically powers back on when the
power is reconnected; if power was off, the appliance stays off when the power is reconnected. If
necessary, power on the appliance with the button on the front of the chassis.
Replacement power supplies are shipped with replacement instructions. Refer to that document when
replacing a faulty power supply.
NGFW Fans
The NGFW Appliances include three cooling fans. The fans for the NGFW S3000/S8000 Series
appliances are redundant and hot-pluggable, and can be replaced without powering down the appliance.