HP 6631B Bedienungsanleitung Seite 47

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 75
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 46
Front Panel Operation - 5
47
7 - Saving and Recalling Operating States
NOTE: This capability is only available when the unit is set to the SCPI programming
language.
You can save up to 4 states (from location 0 to location 3) in non-volatile memory and recall them
from the front panel. All programmable settings are saved.
Save an operating state in location 1 as follows:
Action Display
1. Set the instrument to the operating state that you want to save.
2. Save this state to location 1. Press Save, 1, Enter. *SAV 1
Recall a saved state as follows:
Action Display
1. Recall the state saved in location 1 by pressing Recall, 1, Enter *RCL 1
Select the power-on state of the dc source as follows:
Action Display
1. On the Function keypad, press Output, and scroll through the Output
menu until you get to the PON state command.
PON:STATE RST
2. Use the ã and ä keys to select either RST or RCL0. RST sets the power-
on state of the unit as defined by the *RST command. RCL0 sets the
power-on state of the unit to the state saved in *RCL location 0.
Clear the non-volatile memory of the dc source as follows:
Action Display
1. On the Function keypad, press Output, Enter. This returns the unit to
the factory-default settings.
*RST
2. Save these settings to location 1. Press Save, 1, Enter. *SAV 1
3. Repeat step #2 for memory locations 2 through 4.. *SAV 2
*SAV 3
*SAV 4
Seitenansicht 46
1 2 ... 42 43 44 45 46 47 48 49 50 51 52 ... 74 75

Kommentare zu diesen Handbüchern

Keine Kommentare