Hp procurve J8164A Bedienungsanleitung Seite 23

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 22
3-7
Planning
Planning Your PoE Configuration
Planning
With an HP 600 RPS/EPS Powering Two Switches
The lowest loaded bank of ports (1-24 or 25-48) has 38 W reserved and is
‘bank 2’ in the table above.
Source of
Power
Watts
Available
# of Ports Powered and
Average Watts/Port
Redundant # of Ports
Powered and Average Watts/
Port
Internal PoE
Power
Supply
406 24 @ average 15.4 W each
48 @ average 8.45 W each
Internal plus
External PoE
Power
Supply
406 184
1 - 24 25 - 48
24 @ average 15.4 W each
and 24 @ 7.6 W each
or
36 @ average 15.4 W each
External PoE
Power
Supply
(Failed
Internal PoE
Power
Supply)
184
(38 W is
reserved for
either 1-24 or
25-48)
9 (bank 1) and 2 (bank 2) @
average 15.4 W each
19 (bank 1) and 5 (bank 2) @
average 7.6 W each
48 @ average 3.8 W each
Second PoE Switch/Module
+
Seitenansicht 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 31 32

Kommentare zu diesen Handbüchern

Keine Kommentare