HP ProLiant ML370 G5 Model (tower)
HP ProLiant ML370 G5 Model (tower)HP ProLiant ML370 G5 Model (tower)
HP ProLiant ML370 G5 Model (tower)
Front View:
Front View:Front View:
Front View:
Rear View:
Rear View:Rear View:
Rear View:
1.
System Insight Display (SID)
2.
Media Bay Spacer (Tower)/Video Connector (Rack)
3.
DVD/CD-ROM Drive
4.
Removable Media Bays
5.
Front Bezel (Tower Model Only)
6.
Hard Drive Bays 1-8 (Serial-attached SCSI (SAS) drives
supported - SFF)
7.
Hard Drive Bays 9-16 - Optional Drive Cage (Serial-
attached SCSI (SAS) drives supported - SFF)
8.
Integrated RAID Controller Slot
9.
(2) PCI-X 64 Bit/133MHz Slot
10.
(6) PCI-Express x4 Slot
11.
(8) PC2-5300 Fully Buffered DIMM Slots per memory card -
Standard
12.
(8) PC2-5300 Fully Buffered DIMM Slots per memory card -
Optional
13.
Dual-Core Intel Xeon processor - Optional
14.
Dual-Core Intel Xeon processor - Standard (2 processors
standard on all Performance Models)
15.
(3) Hot Plug Redundant Fans - Standard
16.
(3) Hot Plug Redundant Fans - Optional
1.
Keyboard connector
2.
Mouse connector
3.
USB connectors
4.
Integrated Lights-Out 2 (iLO 2) management connector
5.
Video connector
6.
Serial connector
7.
NIC 2 connector
8.
PCI expansion slots
9.
Hot-plug power supply (primary bay)
10.
Hot-plug power supply blank (redundant bay)
11.
NIC 1 connector
12.
T-15 Torx screwdriver
QuickSpecs
HP ProLiant ML370 Generation 5 (G5)
HP ProLiant ML370 Generation 5 (G5)HP ProLiant ML370 Generation 5 (G5)
HP ProLiant ML370 Generation 5 (G5)
Overview
DA - 12478 Worldwide — Version 23 — November 14, 2007
Page 1
Seitenansicht 0
1 2 3 4 5 6 ... 45 46

Inhaltsverzeichnis

Seite 1 - QuickSpecs

HP ProLiant ML370 G5 Model (tower)HP ProLiant ML370 G5 Model (tower)HP ProLiant ML370 G5 Model (tower)HP ProLiant ML370 G5 Model (tower) Front View:Fr

Seite 2

ROMPaq, supportsoftware, andconfiguration utilitiesThe latest software, drivers, and firmware fully optimized and tested for yourProLiant server and o

Seite 3

Optional RemoteManagement PacksIntegrated Lights-Out Advanced PackIntegrated Lights-Out Advanced PackIntegrated Lights-Out Advanced PackIntegrated Lig

Seite 4

Power SupplyPower SupplyPower SupplyPower Supply800 Watt-CE Mark Compliant Hot Plug Power Supply (1000 Watt high line)Optional second Power Supply pro

Seite 5

Rack AirflowRack AirflowRack AirflowRack AirflowRequirementsRequirementsRequirementsRequirementsRack 10000 series CabinetsRack 10000 series CabinetsRa

Seite 6

HP EnterpriseHP EnterpriseHP EnterpriseHP EnterpriseConfiguratorConfiguratorConfiguratorConfiguratorThe HP eCo-Enterprise Configurator now provides fa

Seite 7

NOTE: NOTE: NOTE: NOTE: ProLiant Smart Buys are available in NA only. For detailed specification information on ProLiant Smart Buys please click onthe

Seite 8

458344-xx1ML370R05 E5430ML370R05 E5430ML370R05 E5430ML370R05 E5430458346-xx1ML370R05 E5320ML370R05 E5320ML370R05 E5320ML370R05 E5320433751-xx1ML370R05

Seite 9

NOTE:NOTE:NOTE:NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areord

Seite 10

Step 2: Choose Required Options (only one of the following from each list)Step 2: Choose Required Options (only one of the following from each list)St

Seite 11

Step 3: Choose Additional Factory Integratable OptionsStep 3: Choose Additional Factory Integratable OptionsStep 3: Choose Additional Factory Integrat

Seite 12

HP ProLiant ML370 G5 Model (Rack)HP ProLiant ML370 G5 Model (Rack)HP ProLiant ML370 G5 Model (Rack)HP ProLiant ML370 G5 Model (Rack)Front View:Front V

Seite 13

NOTE: NOTE: NOTE: NOTE: Some options may not be factory configurable. Please contact your local sales representative for additional information.HP Pro

Seite 14

physical shipment. The license entitlement certificate must be redeemed online or viafax in order to obtain the license activation key(s). Includes on

Seite 15

ProcessorProcessorProcessorProcessorQuad-core Intel Xeon Processor X5460 (3.16 GHz, 120 Watts, 1333 FSB)458408-B21Quad-core Intel Xeon Processor X5450

Seite 16

Optical DrivesOptical DrivesOptical DrivesOptical DrivesCD-RW/DVD-ROM Combo Drive Option Kit331346-B21HP DVD±R/RW 16X Half Height383974-B21Serial Port

Seite 17

512MB Battery-backed cache upgradeNOTE: NOTE: NOTE: NOTE: Supports the Smart Array P400 Controller.405148-B21Battery-backed write cache upgradeNOTE:NO

Seite 18

(Single Channel Ultra320 SCSI HBA)http://h18000.www1.hp.com/products/quickspecs/11587_div/11587_div.html(Smart Array 6400 Series)http://h18000.www1.hp

Seite 19

HP StorageWorks LTO-3 Ultrium 920 SAS Internal Tape DriveEH847ANOTE: NOTE: NOTE: NOTE: Please refer to the "Tape Drives, Tape Autoloaders & T

Seite 20

HP D2D Backup SystemHP D2D Backup SystemHP D2D Backup SystemHP D2D Backup SystemHP StorageWorks D2D110 Backup SystemNOTE: NOTE: NOTE: NOTE: 1TB of Dis

Seite 21

HP StorageWorks MSL8096 2 Ultrium 920 SAS Drive LibraryAH561AHP StorageWorks MSL8096 2 Ultrium 960 4GB FC LibraryAH218AHP StorageWorks MSL8096 2 Ultri

Seite 22

StorageWorksStorageWorksStorageWorksStorageWorksOptionsOptionsOptionsOptionsNOTE: NOTE: NOTE: NOTE: The following is a list of all Fibre Channel Host

Seite 23

Servers support up to 2 processors (2 processors standard on all Performance models)Preconfigured Performance models save valuable deployment time at

Seite 24

HP StorageWorksHP StorageWorksHP StorageWorksHP StorageWorksModular Smart ArrayModular Smart ArrayModular Smart ArrayModular Smart Array10001000100010

Seite 25

Modular PowerModular PowerModular PowerModular PowerDistribution Units 1U/0UDistribution Units 1U/0UDistribution Units 1U/0UDistribution Units 1U/0U(u

Seite 26

HP Rack 5000 SeriesHP Rack 5000 SeriesHP Rack 5000 SeriesHP Rack 5000 Series(Graphite Metallic)HP 5642 Rack-Unassembled358254-B21NOTE:NOTE:NOTE:NOTE:

Seite 27

Keyboards and MonitorsKeyboards and MonitorsKeyboards and MonitorsKeyboards and MonitorsTFT7210R Rack Mounted 17" Monitor348373-B21TFT7600 Rackmo

Seite 28

HP KVM Switch OptionsHP KVM Switch OptionsHP KVM Switch OptionsHP KVM Switch Options2x1x16 IP Console Switch with Virtual MediaAF601A4x1x16 IP Console

Seite 29

Service and SupportService and SupportService and SupportService and SupportOfferings Offerings Offerings Offerings (HP Care PackServices)Hardware Ser

Seite 30

NOTE:NOTE:NOTE:NOTE: Memory configurations listed do not apply to "Factory Integrated Models".NOTE:NOTE:NOTE:NOTE: Memory DIMMs in systems w

Seite 31

ADVD-ROM Drive (Performance Models)/48x IDECD-ROM Drive (Base and Entry Models)B, CDVD-ROM Drive (Performance Models)/48x IDECD-ROM Drive (Base and En

Seite 32

Hard DrivesHard DrivesHard DrivesHard DrivesSFF SATA Hot Plug DrivesSFF SATA Hot Plug DrivesSFF SATA Hot Plug DrivesSFF SATA Hot Plug Drives QuantityQ

Seite 33

to determineconfigurationrequirementsTape Drives, Tape Autoloaders, Tape Libraries & D2D BackupTape Drives, Tape Autoloaders, Tape Libraries &

Seite 34

have a one-year warranty.NOTE: NOTE: NOTE: NOTE: Server Warranty includes 3-Year Parts, 3-Year Labor, 3-Year Onsite support with next business day res

Seite 35

3U Rack-Mount Kit HP StorageWorks USBHP StorageWorks USBHP StorageWorks USBHP StorageWorks USBTape Drives, InternalTape Drives, InternalTape Drives,

Seite 36

HP StorageWorks SASHP StorageWorks SASHP StorageWorks SASHP StorageWorks SASTape Automation,Tape Automation,Tape Automation,Tape Automation,ExternalEx

Seite 37

Part NumberPart NumberPart NumberPart Number380622-001Spare KitSpare KitSpare KitSpare Kit403781-001Operational Input Voltage Range (VOperational Inpu

Seite 38

System UnitSystem UnitSystem UnitSystem UnitTower DimensionsTower DimensionsTower DimensionsTower Dimensions(H x W x D) (with bezel)18.38 x 8.63 x 28.

Seite 39

sustained sunlight. Maximum rate of change is10°C/hr (18°F/hr). The upper limit may belimited by the type and number of optionsinstalled.System perfor

Seite 40

Smart Array P400Smart Array P400Smart Array P400Smart Array P400ControllerControllerControllerControllerDisk Drive and EnclosureDisk Drive and Enclosu

Seite 41

Two embedded NC373iTwo embedded NC373iTwo embedded NC373iTwo embedded NC373iMultifunction GigabitMultifunction GigabitMultifunction GigabitMultifuncti

Seite 42

NOTE:NOTE:NOTE:NOTE: For a brief, printer friendly data sheet that describes this product and informs you of the essential capabilities andspecificati

Seite 43

UpgradeabilityUpgradeabilityUpgradeabilityUpgradeabilityUpgradeable to 2 processorsNOTE: NOTE: NOTE: NOTE: Please contact your regional sales support

Seite 44

NOTE: NOTE: NOTE: NOTE: x8 cards are supported but will run at x4 speeds. X8 speed can be supported with optional PCIEx4/x8 expansion card option on s

Seite 45

Intelligent ManageabilityIntelligent ManageabilityIntelligent ManageabilityIntelligent ManageabilityHP Systems Insight ManagerSmartStartManagement Age

Seite 46

ProLiant EssentialsProLiant EssentialsProLiant EssentialsProLiant EssentialsFoundation PackFoundation PackFoundation PackFoundation PackSoftwareSoftwa