Hp ProLiant DL320s Server Bedienungsanleitung Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 100
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
Component identification 12
Item
Description Item Description
1 PCI Express x8 connector 10 Fan 3 connector
2 PCI Express x1 connector 11 Fan 4 connector
3 System maintenance switch
(on page 12)
12 Main power connector
4 NMI switch ("NMI
functionality" on page 13)
13 Processor socket
5 Battery 14 Auxiliary power connector
6 Front panel LED board
connector
15 DIMM slot 1 (bank A)
7 Internal USB connector 16 DIMM slot 2 (bank B)
8 Fan 1 connector 17 DIMM slot 3 (bank A)
9 Fan 2 connector 18 DIMM slot 4 (bank B)
System maintenance switch
Position Default Function
S1 Off Off = iLO 2 security is enabled
On = iLO 2 security is disabled
S2 Off Off = Normal operation
On = RBSU will not commit any
configuration changes *
S3 Off Reserved
S4 Off Off = Normal operation
On = Override RBSU setting and
enable diskette boot *
S5 Off Off = Power-on password enabled
On = Power-on password disabled *
S6 Off Off = Normal operation
On = BIOS will clear CMOS and
NVRAM *
S7 Off Reserved
S8 Off Reserved
* "On" activates the function.
When the system maintenance switch position 6 is set to the On position, the system is prepared to erase
all system configuration settings from both CMOS and NVRAM.
CAUTION: Clearing CMOS and/or NVRAM deletes configuration information. Be sure to
properly configure the server or data loss could occur.
Seitenansicht 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 99 100

Kommentare zu diesen Handbüchern

Keine Kommentare