Seite 1 - User Guide

HP Smart Array P600 Controller for Integrity Servers User Guide July 2005 (First Edition) Part Number 398844-001

Seite 2 - Audience assumptions

10 HP Smart Array P600 Controller for Integrity Servers User Guide 3. Power down all peripheral devices that are attached to the server. 4. Unpl

Seite 3 - Contents

Installing the controller hardware 11 CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating the

Seite 4

12 HP Smart Array P600 Controller for Integrity Servers User Guide Cable length Option kit number Cable assembly number 6.0 m (20 ft) 389674-B2

Seite 5 - Hardware features

13 Updating the firmware In this section Methods for updating the firmware (Windows® or Linux®) ...

Seite 7

15 Configuring an array In this section Introduction ...

Seite 8

16 HP Smart Array P600 Controller for Integrity Servers User Guide For conceptual information about arrays, logical drives, and fault-tolerance me

Seite 9 - Preparing the server

Configuring an array 17 Using ORCA 1. Power up the server. POST runs, and any array controllers that are in the server are initialized one at a

Seite 10

18 HP Smart Array P600 Controller for Integrity Servers User Guide 4. Press the F8 key to confirm the settings and save the new configuration. Af

Seite 11 - SAS cable part numbers

19 Installing device drivers and Management Agents In this section Systems using Microsoft® Windows® ...

Seite 12

© Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties f

Seite 13 - Updating the firmware

20 HP Smart Array P600 Controller for Integrity Servers User Guide The most recent version of the software component is available on the support p

Seite 14

Installing device drivers and Management Agents 21 Novell (SLES): #mkinitrd -k /boot/vmlinux -i/boot/initr 5. For Novell, enter the following co

Seite 16 - Comparing the utilities

23 Upgrading or replacing controller options In this section Replacing a battery ...

Seite 17 - Using ORCA

24 HP Smart Array P600 Controller for Integrity Servers User Guide 3. If the main cache battery must be replaced: a. Press the battery retainer

Seite 18 - Using ACU

Upgrading or replacing controller options 25 5. Replace whichever battery is degraded. 6. Reinstall the batteries on the cache board and the co

Seite 20 - Systems using Linux®

27 Replacing, moving, or adding hard drives In this section Identifying the status of a hard drive...

Seite 21 - Installing Management Agents

28 HP Smart Array P600 Controller for Integrity Servers User Guide Online/Activity LED (green) Fault/UID LED (amber/blue) Interpretation On, off,

Seite 22

Replacing, moving, or adding hard drives 29 Recognizing hard drive failure A steadily glowing Fault LED indicates that that drive has failed. Oth

Seite 23 - Replacing a battery

3 Contents Hardware features 5 Board components...

Seite 24

30 HP Smart Array P600 Controller for Integrity Servers User Guide • RAID 5 configurations can tolerate one drive failure. • RAID ADG configurat

Seite 25

Replacing, moving, or adding hard drives 31 4. After you have replaced the failed drives, fault tolerance may again be compromised. If so, cycle

Seite 26

32 HP Smart Array P600 Controller for Integrity Servers User Guide Factors to consider before replacing hard drives Before replacing a degraded dr

Seite 27 -

Replacing, moving, or adding hard drives 33 The following cases are exceptions: – In RAID ADG configurations, any two drives in the array can be

Seite 28

34 HP Smart Array P600 Controller for Integrity Servers User Guide • The amount of unused capacity on the drives • The number of drives in the a

Seite 29

Replacing, moving, or adding hard drives 35 1. Back up as much data as possible from the logical drive. CAUTION: Do not remove the drive tha

Seite 30 - Compromised fault tolerance

36 HP Smart Array P600 Controller for Integrity Servers User Guide 1. Remove the drive that was originally to be replaced, and reinsert the repla

Seite 31 - Replacing hard drives

Replacing, moving, or adding hard drives 37 Before you move drives, the following conditions must be met: • The server must be powered down. •

Seite 32

38 HP Smart Array P600 Controller for Integrity Servers User Guide Adding drives You can add hard drives to a system at any time, as long as you d

Seite 33

Replacing, moving, or adding hard drives 39 When the expansion process has finished, you can use the liberated storage capacity on the enlarged a

Seite 34

4 HP Smart Array P600 Controller for Integrity Servers User Guide Recognizing hard drive failure...

Seite 36 - Moving drives and arrays

41 Diagnosing array problems In this section Controller board runtime LEDs...

Seite 37

42 HP Smart Array P600 Controller for Integrity Servers User Guide LED ID Color LED name and interpretation 4 Green CR514: Command Outstanding

Seite 38 - Adding drives

Diagnosing array problems 43 Cache module LEDs Item 1 (amber LED) Item 2 (green LED) Interpretation -- Steady glow The cache batteries are be

Seite 39

44 HP Smart Array P600 Controller for Integrity Servers User Guide Diagnostic tools Several diagnostic tools provide feedback about problems wit

Seite 40

45 Electrostatic discharge In this section Preventing electrostatic discharge ...

Seite 41 - Diagnosing array problems

46 HP Smart Array P600 Controller for Integrity Servers User Guide Grounding methods to prevent electrostatic discharge Several methods are used f

Seite 42

47 Regulatory compliance notices In this section Federal Communications Commission notice...

Seite 43 - Cache module LEDs

48 HP Smart Array P600 Controller for Integrity Servers User Guide Class A equipment This equipment has been tested and found to comply with the l

Seite 44 - Diagnostic tools

Regulatory compliance notices 49 Declaration of conformity for products marked with the FCC logo, United States only This device complies with Part

Seite 45 - Electrostatic discharge

5 Hardware features In this section Board components...

Seite 46

50 HP Smart Array P600 Controller for Integrity Servers User Guide Canadian notice (Avis Canadien) Class A equipment This Class A digital apparatu

Seite 47 - FCC rating label

Regulatory compliance notices 51 BSMI notice Japanese notice

Seite 48 - Class B equipment

52 HP Smart Array P600 Controller for Integrity Servers User Guide Korean notice A&B Class A equipment Class B equipment Battery replacemen

Seite 49 - Modifications

Regulatory compliance notices 53 • Do not attempt to recharge the batteries if they are disconnected from the controller. • Do not expose the ba

Seite 51 - Japanese notice

55 Acronyms and abbreviations ACR Array Configuration Replicator ACU Array Configuration Utility ADG Advanced Data Guarding (also known as RAI

Seite 52 - Battery replacement notice

56 HP Smart Array P600 Controller for Integrity Servers User Guide POST Power-On Self Test RAID redundant array of inexpensive (or independent) d

Seite 53

57 Index A ACU (Array Configuration Utility) 18 adding drives 38 array capacity expansion 38 array controller installation overview 7 ar

Seite 54

58 HP Smart Array P600 Controller for Integrity Servers User Guide J Japanese notice 51 K Korean notices 52 L LEDs, cache module 43 LEDs, co

Seite 55 - Acronyms and abbreviations

6 HP Smart Array P600 Controller for Integrity Servers User Guide *Ports 1E and 1I share electrical circuitry. Whenever the controller is reset, i

Seite 56

7 Overview of the installation procedure In this section Quick installation procedure (Windows® or Linux®)...

Seite 57

8 HP Smart Array P600 Controller for Integrity Servers User Guide If the server is using Linux®, controller installation is complete. When the ser

Seite 58

9 Installing the controller hardware In this section Before beginning the installation...............