Hp NetRAID 1Si Controller Bedienungsanleitung Seite 34

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 161
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 33
Chapter 2 HP NetRAID Assistant
28
3. Reset the rate as necessary by dragging the slider with the mouse.
4. Click OK.
5. If you have more than one adapter, select the next adapter, and repeat this
procedure.
NOTE Clearing the configuration does not affect the rebuild rate.
Assign Global Hot Spares
To assign any physical drives to the global hot spare pool for the adapter:
1. Click on a Ready physical drive in the Physical Devices box.
You can select more than one Ready drive if you want to create more than
one global hot spare. Clicking on a Ready drive either selects it or
deselects it.
2. Drag the selected drives into the global hot spare pool.
Select Wizard
NOTE If any physical drives have been moved, added, removed,
changed, or changed in state since HP NetRAID Assistant was
started, rescan the drives by choosing the Adapter menu and
then selecting the Rescan option.
To launch the HP NetRAID Assistant Wizard:
1. Select the Configuration menu.
2. Choose the Wizard. The Wizard starting window is displayed with a
choice of Custom and Automatic configuration modes, as shown in
Figure 2-4.
Seitenansicht 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 ... 160 161

Kommentare zu diesen Handbüchern

Keine Kommentare