Hp NC3131 Fast Ethernet Server Adapter Bedienungsanleitung Seite 32

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 31
Specifications C-9
Fiber Cable Specifications
To connect to the network, the NC3133, NC6132, and NC6133 upgrade modules use
100 BASE-FX, 1000 BASE-SX, or 1000BASE-LX fiber cable specifications, respectively.
Table C-13 and Table C-14 describe the fiber types, mode, cable size, and maximum distance
specifications for the fiber upgrade modules.
NOTE: All fiber upgrade modules use SC type connectors.
Table C-13
Fiber Cable Maximum Distances for 1000BASE-SX, 1000BASE-LX
(NC6132 and NC6133)
Fiber Type Mode Size Max Distance
1000BASE-SX Multimode
62.5/125 µm
220 meters
Multimode
50/125 µm
550 meters
1000BASE- LX Multimode
62.5/125 µm
550 meters
Multimode
50/125 µm
550 meters
Single-mode
10µm
5000 meters
Table C-14
Fiber Cable Maximum Distances for 100BASE-FX (NC3133)
Single Link Between Switches Mode Max Distance
FX Multimode 2000 meters
FX Multimode 25 km
Seitenansicht 31
1 2 ... 27 28 29 30 31 32

Kommentare zu diesen Handbüchern

Keine Kommentare