Hp StorageWorks 1510i Modular Smart Array Bedienungsanleitung Seite 56

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 99
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 55
2. To enter an initiator-specicCHAPsecretinboththeSMUandintheiSCSIinitiatorsoftwareutility:
a. On the server, open the iSCSI initiator software utility. Navigate through the iSCSI initiator
software utility and either assign a CHAP secret to the initiator or record the existing CHAP
secret.
b. In the SMU, select Initiator > CHAP Settings. Then, enter the same CHAP secret assigned to
the initiator the iSCSI initiator software utility.
3. On the server, open the iSCSI initiator software utility. Navigate through the iSCSI initiator software
utility to locate and select the option to perform mutual authentication.
Setting the SSL certicate
ASecureSocketsLayer(SSL)certicate provides browser security, ensuring a secure connection between
the array controller and an initiating server, over which any amount of data can be sent securely. SSL
works by using a private key to encrypt data transferred over the internet.
The array controller ships with a default certicate already installed, but until a server-specic certicate is
installed, a warning message is displayed when accessing the SMU.
SSL certicate implementation on the MSA1510i makes use of PEM formatted les. Microsoft Certicate
Servi
ces do not directly support the PEM le format, but the publicly available OpenSSL toolset is
recommended for generating required keys and certicates or for converting Microsoft private key
exports into PEM format. For more information, see the HP Storageworks Modular Smart Array 1510i
Advanced Planning and Conguration Guide.
To upload your server-specicSSLcerticate: