HP 518851-B21 Datenblatt

Stöbern Sie online oder laden Sie Datenblatt nach Server HP 518851-B21 herunter. HP ProLiant 518851-B21 server Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 44
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
HP ProLiant BL465c G7 Server Blade
HP ProLiant BL465c G7 Server BladeHP ProLiant BL465c G7 Server Blade
HP ProLiant BL465c G7 Server Blade
1.
Smart Array P410i storage controller (available as an option
in factory integrated models)
5.
Up to two (2) Multi-Core AMD Opteron™ 6100 Series
processors
2.
Two (2) small form factor (SFF) hot plug drive bays
6.
System power button and LED
3.
Internal USB connector
Internal MicroSD card slot
7.
Local I/O connector
QuickSpecs
HP ProLiant BL465c Generation 7 (G7) Server Blade
HP ProLiant BL465c Generation 7 (G7) Server BladeHP ProLiant BL465c Generation 7 (G7) Server Blade
HP ProLiant BL465c Generation 7 (G7) Server Blade
Overview
DA - 13654 North America — Version 18 — November 14, 2011
Page 1
Seitenansicht 0
1 2 3 4 5 6 ... 43 44

Inhaltsverzeichnis

Seite 1 - QuickSpecs

HP ProLiant BL465c G7 Server BladeHP ProLiant BL465c G7 Server BladeHP ProLiant BL465c G7 Server BladeHP ProLiant BL465c G7 Server Blade1.Smart Array

Seite 2

virtual machine to complex multi-tier environments and their associatedphysical and virtual resource requirements. In addition to the previousfunction

Seite 3

AvailabilityAvailabilityAvailabilityAvailabilityDual-Port Fibre Channel Mezzanine Card for redundant SAN connectionEmbedded dual-port 10Gb Converged N

Seite 4

Factory Express PortfolioFactory Express PortfolioFactory Express PortfolioFactory Express Portfoliofor Servers and Storagefor Servers and Storagefor

Seite 5

Service and SupportService and SupportService and SupportService and SupportHP Technology Services for Industry Standard Servers and BladeSystemHP Tec

Seite 6

Standard Care PackageStandard Care PackageStandard Care PackageStandard Care PackagePackage that maintains high level of server availabilityPackage th

Seite 7

Provides for the deployment and basic configuration of HP Insight Control on HP ProLiant ML and DLseries servers or HP BladeSystem servershttp://h2019

Seite 8

Sixteen-Core ModelsSixteen-Core ModelsSixteen-Core ModelsSixteen-Core ModelsNOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factor

Seite 9

Plug 2 SFF ServerPlug 2 SFF ServerPlug 2 SFF ServerPlug 2 SFF Server518859-B21HP ProLiant BL465c G7HP ProLiant BL465c G7HP ProLiant BL465c G7HP ProLia

Seite 10

HP BL465c G7 6134 4HP BL465c G7 6134 4HP BL465c G7 6134 4HP BL465c G7 6134 4GB Svr/S-BuyGB Svr/S-BuyGB Svr/S-BuyGB Svr/S-Buy630443-S01Processor(s)Proc

Seite 11

HP BL465c G7 6272 2PHP BL465c G7 6272 2PHP BL465c G7 6272 2PHP BL465c G7 6272 2P48 GB Svr/S-Buy48 GB Svr/S-Buy48 GB Svr/S-Buy48 GB Svr/S-Buy663063-S01

Seite 12

4.Two (2) mezzanine I/O expansion slots8.Sixteen (16) PC3-8500 DDR3 Registered DIMMs, PC3-10600DDR3 Registered DIMMs, or PC3-10600 DDR3 UnbufferedDIMM

Seite 13

NOTE:NOTE:NOTE:NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areord

Seite 14

HP BL465c G7 AMD Opteron™ 6220 (3.0GHz/8-core/16MB/115W) FIO ProcessorKit655095-L21HP BL465c G7 AMD Opteron™ 6212 (2.60GHz/8-core/16MB/115W) FIOProces

Seite 15

NOTE:NOTE:NOTE:NOTE: Each processor memory bus will operate at up to 1333 MHz with either onequad-rank (QR) or two single-rank/dual-rank (SR/DR) DIMMs

Seite 16

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Seite 17

HP ProcessorsHP ProcessorsHP ProcessorsHP ProcessorsSixteen-Core ProcessorsSixteen-Core ProcessorsSixteen-Core ProcessorsSixteen-Core Processors HP BL

Seite 18

HP 8GB (1x8GB) Single Rank x4 PC3-12800 (DDR-1600) Registered CAS-11Memory Kit676333-B21HP 8GB (1x8GB) Dual Rank x4 PC3-10600 (DDR3-1333) Registered C

Seite 19

HP 900GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty HardDrive S-Buy619291-S21HP 600GB 6G SAS 10K rpm SFF (2.5-inch) Dual Port Ent

Seite 20

6G SAS Hot Plug Enterprise Mainstream Solid State Drives6G SAS Hot Plug Enterprise Mainstream Solid State Drives6G SAS Hot Plug Enterprise Mainstream

Seite 21

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Seite 22

NOTE:NOTE:NOTE:NOTE: Electronic licenses can be used to purchase multiple licenses with a singleactivation key.NOTE:NOTE:NOTE:NOTE: Customer will rece

Seite 23

Integrated Models section for more information.Internal Drive SupportInternal Drive SupportInternal Drive SupportInternal Drive Support:Up to two (2)

Seite 24

HP Security - TPMHP Security - TPMHP Security - TPMHP Security - TPMHP Trusted Platform Module Option488069-B21NOTE:NOTE:NOTE:NOTE: The TPM key is uni

Seite 25

HP Ultrium Tape BladesHP Ultrium Tape BladesHP Ultrium Tape BladesHP Ultrium Tape BladesHP LTO-4 SB1760c Tape BladeNOTE:NOTE:NOTE:NOTE: LTO-4 Ultrium

Seite 26

HP Care Pack ServicesHP Care Pack ServicesHP Care Pack ServicesHP Care Pack ServicesNOTE:NOTE:NOTE:NOTE: The HP Care Pack service part numbers below f

Seite 27

NOTE:NOTE:NOTE:NOTE: Memory configurations listed do not apply to "Factory Integrated Models".DDR3 Memory Population GuidelinesDDR3 Memory P

Seite 28

channels, the maximum speed will be 1066MHzReferences to the above MHz speeds are for the various speeds of DDR3 DIMMs; 1333 refers to DDR3-1333, etc.

Seite 29

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11A: 4GB DIMM1A: emptyChnl 12E: 16GB DIMM2E: empty Chn

Seite 30

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11A: 4GB DIMM1A: emptyChnl 12E: 4GB DIMM2E: empty Chnl

Seite 31

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11A: 4GB DIMM1A: 4GB DIMMChnl 12E: 4GB DIMM2E: 4GB DIMM

Seite 32

HP 4GB (1x4GB) Dual Rank x8 PC3-10600 (DDR3-1333) Unbuffered CAS-9Memory Kit593923-B21NOTE:NOTE:NOTE:NOTE: All DDR3 memory option kits consist of one

Seite 33

1-22 x SFF SAS or SATA Hot Plug Hard Drives, or2 x SFF SATA Hot Plug SSD DrivesHard DrivesHard DrivesHard DrivesHard DrivesNOTE:NOTE:NOTE:NOTE: The co

Seite 34

The HP BladeSystem c3000 rack enclosure is 6U high and holds up to eight (8) HP ProLiant BL465c G7 serversplugged horizontally.Server blades, storage

Seite 35

400GB 6G SAS SLC SFF200GB 6G SAS SLC SFF21-2Smart Array P410i Controller6G SAS Hot Plug Enterprise Mainstream Solid State Drives6G SAS Hot Plug Enterp

Seite 36

System UnitSystem UnitSystem UnitSystem UnitDimensionsDimensionsDimensionsDimensions(H x W x D)7.154 x 2.19 x 20.058 in (18.17 x 5.56 x 50.95 cm)Weigh

Seite 37

Enclosures QuickSpecs located at URL:HP BladeSystem c3000 Enclosure QuickSpecs:http://h18000.www1.hp.com/products/quickspecs/12790_na/12790_na.htmlHP

Seite 38

HP Integrated Lights-OutHP Integrated Lights-OutHP Integrated Lights-OutHP Integrated Lights-Out3 (iLO 3)3 (iLO 3)3 (iLO 3)3 (iLO 3)integrated on syst

Seite 39

Environment-friendlyEnvironment-friendlyEnvironment-friendlyEnvironment-friendlyProducts and ApproachProducts and ApproachProducts and ApproachProduct

Seite 40

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information -

Seite 41

MemoryMemoryMemoryMemoryTypeDDR3 Registered (RDIMM) or Unbuffered (UDIMM)Standard8 GB (2 x 4 GB)Maximum (RDIMM)512 GB (16 x 32 GB) at 1333 MHzMaximum

Seite 42

Maximum InternalMaximum InternalMaximum InternalMaximum InternalStorageStorageStorageStorageOne of the followingdepending on ModelHot Plug SAS2TB SAS

Seite 43

Support for Microsoft® Windows®, Linux, VMware ESX and Citrix XenServer™ operating systemenvironmentsCompatible SANCompatible SANCompatible SANCompati

Seite 44

following:Its Media Kit (contains 2 SmartStart CDs, the Firmware DVD, and theManagement DVD) will continue to ship with all supported ProLiantG7 or ea

Kommentare zu diesen Handbüchern

Keine Kommentare