HP SAN Switch Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Netzwerk-Switches HP SAN Switch herunter. HP SAN Switch User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 104
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
McDATA
®
4Gb SAN Switch
for HP p-Class BladeSystem user guide
Part number: AA-RW20C-TE
Third edition: November 2006
Seitenansicht 0
1 2 3 4 5 6 ... 103 104

Inhaltsverzeichnis

Seite 1 - 4Gb SAN Switch

McDATA® 4Gb SAN Switchfor HP p-Class BladeSystem user guidePart number: AA-RW20C-TE Third edition: November 2006

Seite 2

10Helpful web sitesFor other product information, see the following HP web sites:• http://www.hp.com • http://www.hp.com/go/storage • http://www.hp.co

Seite 4

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 101IndexAactive zone set 38, 44Active Zoneset data window 44administrative stateconfigure

Seite 5

102Fabric Device Management Interface 72factory defaults 80FC-4 descriptor 94FDMI - See Fabric Device Management InterfaceFile Transfer Protocol 74fir

Seite 6

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 103QQuickTools 15RRADIUS - See Remote Authentication Dial-In User Serviceread community 7

Seite 7 - About this guide

104Wweb server service 74web sitesHP documentation 7HP storage 10HP Subscriber’s choice 9wizard, configuration 68working directory 14workstation requi

Seite 8 - JDOM license

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 111 Using McDATA Web Server/Element ManagerThis section describes how to use the McDATA W

Seite 9 - HP technical support

12Workstation requirementsThe requirements for fabric management workstations running the McDATA Web Server web applet are listed in Table 2.Starting

Seite 10 - Helpful web sites

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 13Starting Element Manager in HAFMTo use Element Manager, the HAFM client application mus

Seite 11

14Setting preferencesYou can customize the following preference settings for McDATA Web Server and Element Manager:• Change the location of the workin

Seite 12 - Starting McDATA Web Server

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 15Using online helpOnline help is available for the McDATA Web Server and Element Manager

Seite 13

16User interfaceThe McDATA Web Server and Element Manager applications share a common interface as shown in Figure 3. The interface consists of a menu

Seite 14 - Setting preferences

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 17Menu barThe McDATA Web Server and Element Manager menu bar options are listed in Table

Seite 15 - Enabling e-mail support

18Popup menusPopup menus are displayed when you right-click the switch faceplate image in the graphic window. Popup menu options give you quick access

Seite 16 - User interface

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 19McDATA Web Server Fabric treeMcDATA Web Server enables you to manage McDATA 4Gb SAN Swi

Seite 17 - Menu bar

Legal and notice information© Copyright 2006 Hewlett-Packard Development Company, L.P.© Copyright 2006 McDATA Corporation.© Copyright 2006. This softw

Seite 18 - Shortcut keys

20Data windows and tabsThe data window presents a table of data and statistics associated with the selected tab for the switch displayed in the graphi

Seite 19 - Graphic window

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 212 Managing FabricsThis section describes the following tasks that manage fabrics using

Seite 20 - Selecting ports

22Connection securityIMPORTANT: The SSL and SSH services can be managed only with Element Manager, which requires the Element Manager PFE key, and the

Seite 21 - 2 Managing Fabrics

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 23Device securityIMPORTANT: Device security is available only with the McDATA SANtegrity™

Seite 22 - Remote authentication

24Edit Security dialogUse the Edit Security dialog to edit the security configuration on the switch. You can also open and edit a security configurati

Seite 23 - Device security

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 25Create Security Set dialogUse the Create Security Set dialog shown in Figure 6 to creat

Seite 24 - Edit Security dialog

26An empty (no members) security group in the active security set will prevent all connections for that security group type. For example, an empty ISL

Seite 25 - Create Security Group dialog

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 27The conventions for Port security group members are listed below: • You can enter membe

Seite 26

28Editing the security configuration on a switchTo edit a security configuration on the switch from the faceplate display:1. Choose one of the followi

Seite 27

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 29Security Config dialogUse the Security Config dialog, shown in Figure 9, to save the ac

Seite 28

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 3About this guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 29 - Activating a security set

30Deactivating a security setOnly one security set can be active at one time. To deactivate an active security set from the faceplate display: 1. Sele

Seite 30 - Rediscovering a fabric

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 31Displaying the event browserThe Event Browser displays a list of events generated by th

Seite 31 - Displaying the event browser

32Severity is indicated in the severity column using icons as described in Table 4.NOTE: Events (Alarms, Critical, Warning, and Informative) generated

Seite 32 - Sorting the event browser

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 33Filtering the event browserFiltering the Event Browser enables you to display only thos

Seite 33 - Filtering the event browser

34Working with device information and nicknamesDevices are hosts and storage targets connected to the switch. A nickname is a user-definable, meaningf

Seite 34 - Devices data window

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 35Displaying detailed device informationIn addition to the information that is available

Seite 35

36Creating a nicknameTo create a device port nickname:1. Select Fabric >Nicknames to open the Nicknames dialog.2. Choose one of the following metho

Seite 36 - Importing a nicknames file

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 37Zoning a fabricIf HAFM is used to manage the fabric, it is recommended to use HAFM to m

Seite 37 - Zoning a fabric

38Zone setsA zone set is a named group of zones. A zone can be a member of more than one zone set. Each switch in the fabric maintains its own zoning

Seite 38 - Zoning database

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 39Zoning limits and propertiesZoning limits vary depending on the firmware installed on t

Seite 39 - Zoning limits and properties

4Sorting the event browser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Filtering

Seite 40 - Managing the zoning database

40Managing the zoning databaseManaging the zoning database consists of the following:• Editing the zoning database, page 40• Configuring the zoning da

Seite 41

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 41• Click a zone, zone set, or port icon.• Right-click to select a zone set or zone, and

Seite 42 - Default zone

42Configuring the zoning databaseUse the Zoning Config dialog to change the Interop Auto Save and Default Zone configuration parameters. The Default Z

Seite 43 - Managing the active zone set

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 43Restoring the default zoning databaseRestoring the default zoning clears the switch of

Seite 44

44Displaying the configured and active zone setsYou can display the contents of the configured zone set and active zone set with the Configured Zonese

Seite 45 - Removing a zone set

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 45Creating a zone setTo create a zone set:1. Select Zoning > Edit Zoning to open the E

Seite 46 - Managing zones

46Managing zonesManaging zones involves the following:• Creating a zone in a zone set, page 46• Adding zone members, page 47• Renaming a zone or a zon

Seite 47 - Removing a zone member

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 47Adding zone membersYou can zone a port/device by switch domain ID and port number, or t

Seite 48 - Merging fabrics and zoning

48Removing a zone from a zone setTo remove a zone from a zone set:1. Select the zone to be removed in the Edit Zoning dialog. The selected zone will b

Seite 49 - 3 Managing switches

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 493 Managing switchesThis section describes the following tasks that manage switches usin

Seite 50 - Creating user accounts

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 5Port status and operational information. . . . . . . . . . . . . . . . . . . . . . . . .

Seite 51 - Removing a user account

50NOTE: If the same user account exists on a switch and its RADIUS server, that user can login with either password, but the authority and account exp

Seite 52

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 51Removing a user accountTo remove a user account on a switch:1. Select Switch > User

Seite 53 - Modifying a user account

52Changing a user account passwordAny user can change their password for their account, but only the Admin account name can change the password for an

Seite 54 - Configuring RADIUS servers

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 53Modifying a user accountTo modify a user account on a switch:1. Select Switch > User

Seite 55 - Adding a RADIUS server

54Configuring RADIUS serversIMPORTANT: RADIUS server support is available only with the McDATA SANtegrity Enhanced PFE key and can be managed only wit

Seite 56 - Removing a RADIUS server

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 55Adding a RADIUS serverA RADIUS server provides a method to centralize user and device a

Seite 57

56Removing a RADIUS serverRemoving a RADIUS server, disables the remote authentication of devices or users over the network.Figure 23 RADIUS Server In

Seite 58

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 57Editing RADIUS server informationEditing information of a RADIUS server involves changi

Seite 59 - Displaying switch information

58Modifying RADIUS server authentication orderEditing information of a RADIUS server involves changing the configuration of a RADIUS server.Figure 25

Seite 60

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 59Displaying switch informationThe faceplate display and data windows provide the followi

Seite 61

610 Events browser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3111

Seite 62

60Switch status and operational informationThe Switch data window, shown in Figure 26, displays the current status and operational information for the

Seite 63

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 61StatusOperational State Switch operational state: Online, Offline, Diagnostic, DownAdmi

Seite 64 - Port performance statistics

62User LoginUser Name Account nameLogin Level Authority levelSuper User Super user privileges enabled/disabled UserAuthentication Enabled Enforcement

Seite 65

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 63SNMP Enabled SNMP enabled or disabled. Zones/SecurityInterop Mode Interoperability mode

Seite 66 - Paging a switch

64Port performance statisticsThe Port Statistics data window displays port performance data for the selected ports. Click the Port Stats data window t

Seite 67 - Resetting a switch

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 65Configuring port threshold alarmsIMPORTANT: Port threshold alarms can be managed only w

Seite 68 - Configuring a switch

66NOTE: The switch will down a port if a rising trigger alarm is not cleared after three consecutive sample windows.Figure 29 Port threshold alarm exa

Seite 69 - Domain ID and domain ID lock

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 67Resetting a switchResetting a switch reboots the switch using configuration parameters

Seite 70 - Symbolic name

68Configuring a switchYou can configure a switch explicitly or you can use the Configuration Wizard. The Configuration Wizard is a series of dialogs t

Seite 71 - In-band management

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 69Domain ID and domain ID lockThe domain ID is a unique Fibre Channel identifier for the

Seite 72 - Advanced switch properties

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 7About this guideThis manual describes the McDATA® Web Server™ and McDATA Element Manager

Seite 73 - System services

70Table 10 lists the corresponding domain ID values for each interop mode: Standard mode and McDATA Fabric mode.SyslogThe Syslog (Remote Logging) feat

Seite 74

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 71Switch administrative statesThe switch administrative state determines the operational

Seite 75 - Network properties

72Fabric Device Management InterfaceFabric Device Management Interface (FDMI) provides a means to gather and display device information from the fabri

Seite 76 - SNMP properties

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 73Timeout valuesThe switch timeout values determine the timeout values for all ports on t

Seite 77 - SNMP trap configuration

74Use caution when disabling the Embedded GUI, GUI Mgmt, Telnet, SSL, and SSH, as it is possible to disable all access to the switch except through a

Seite 78 - Switch binding

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 75Network propertiesUse the Network Properties dialog shown in Figure 33 to change IP con

Seite 79 - Restoring a switch

76SNMP propertiesUse the SNMP Properties dialog shown in Figure 34 to change SNMP configuration parameters. After making changes, click the OK button

Seite 80

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 77SNMP configurationThe SNMP configuration defines how authentication traps are managed.

Seite 81 - Downloading a support file

78Archiving a switchYou can create an .XML archive file containing the configuration parameters. Basically any data received by McDATA Web Server is a

Seite 82

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 79Restoring a switchRestoring a switch loads the archived switch configuration parameters

Seite 83 - Installing firmware

8Document conventions and symbolsWARNING! Indicates that failure to follow directions could result in bodily harm or death.CAUTION: Indicates that fai

Seite 84 - Displaying hardware status

804. To restore all configuration settings, click the Full Restore tab, then click Restore. To restore selected configuration settings, click the Sele

Seite 85 - 4 Managing ports

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 81Downloading a support fileThe Download Support File option assembles all log files and

Seite 86

82Installing Product Feature Enablement keysA PFE key is a password that you can purchase from your switch distributor or authorized reseller that ena

Seite 87

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 83Installing firmwareInstalling firmware involves loading, unpacking, and activating the

Seite 88 - Port statistics data window

84Displaying hardware statusTo display a summary of the hardware status information in a popup text box, rest the cursor over the chassis LED cluster

Seite 89

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 854 Managing portsThe data windows provide port information and port statistics for selec

Seite 90

86The Port Information data window entries are listed below in Table 17.Table 17 Port information data window entries Entry DescriptionSummaryPort Add

Seite 91 - Viewing and configuring ports

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 87

Seite 92 - Port states

88Port statistics data windowThe Port Statistics data window, shown in Figure 40, displays statistics about port performance. Select one or more ports

Seite 93 - Port types

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 89BB_CreditRecoveryFrameFailure Number of times more frames were lost during a credit rec

Seite 94 - Device scan

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 92. Redistributions in binary form must reproduce the above copyright notice, this list o

Seite 95 - Testing ports

90 LIP(f7,f7) A loop initialization primitive frame used

Seite 96

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 91Viewing and configuring portsPort color and text provide information about the port and

Seite 97 - Glossary

92Port statesThe port administrative state determines the operational state of a port. The port administrative state has two forms: the configured adm

Seite 98

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 93Port typesThe external ports can be configured to self-discover the proper type to matc

Seite 99

94Port speedsExternal ports are capable of transmitting and receiving at 1-Gbps, 2-Gbps, or 4-Gbps. Internal ports are capable of transmitting and rec

Seite 100

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 95Port bindingIMPORTANT: Port binding is available only in Element Manager which requires

Seite 101

96• SerDes level (internal)—The SerDes level test verifies port circuitry. The SerDes level test sends a test frame from the ASIC through the SerDes c

Seite 102

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 97GlossaryActive firmware The firmware image on the switch that is in useActive zone set

Seite 103

98Fabric view file A file containing a set of fabrics that were opened and saved during a previous McDATA Web Server sessionFan Fail LED An LED that i

Seite 104

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem user guide 99Principal switch The switch in the fabric that manages domain ID assignmentsProduct Fea

Kommentare zu diesen Handbüchern

Keine Kommentare